China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Goldway |
Model Number: | UT6000A |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Goldway ECG Board | Type: | UT6000A |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
PN: | C-ECG7131C V1 | Material: | Plastic, PCB |
Apply For: | Patient Monitor | Product Edge: | Technical Engineers With 12 Years Of Experience |
Post-sales Service: | If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned | Supported Language: | English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,Arabic,etc |
Product State: | In Good Condition | Product Peculiarity: | Professional, Reliable,Economic |
MOQ: | 1 Pc | HR Measurement Range:: | 15 – 300 Bpm |
Accuracy:: | ±0.02mV Or ±5% | ST Measurement Range:: | ECG 1 Only; -0.8mV – +0.8 MV |
Sweep Speed:: | 12.5 Mm/s, 25 Mm/s, 50 Mm/s | ||
Highlight: | UT6000A Patient Monitor ECG Board,C-ECG7131C v1 Patient Monitor ECG Board |
PHiliphh Goldway UT6000A Patient Monitor ECG Board C-ECG7131C v1
Hospital Medical Parts PHiliphh Goldway UT6000A Patient Monitor ECG Board C-ECG7131C v1
► Brief Introduction
The Goldway UT6000A ECG Board is a component of the Goldway UT6000A series electrocardiograph (ECG) machines. It is responsible for acquiring and processing the electrical signals from the electrodes placed on a patient's body to generate an electrocardiogram. The ECG board converts the analog electrical signals into digital data, filters out noise, and performs various calculations to display and interpret the ECG waveform. It is a crucial part of the ECG machine that helps in diagnosing heart conditions and monitoring cardiac activity.
► Performing ECG Test
To set the ECG Simulator:
To test the ECG:
► Removing the ECG Module
► Specification
Lead type: | Standard 3-Lead or 5-Lead selectable |
Lead selection: | I, II, III or I, II, III, aVR, aVL, aVF, V |
Display channels: | 2 channels, ECG1, ECG2 |
HR measurement range: | 15 – 300 bpm |
Accuracy: | ±5 bpm or ±1%, whichever is greater |
ST measurement range: | ECG 1 only; -0.8mV – +0.8 mV |
Accuracy: | ±0.02mV or ±5% |
Sweep speed: | 12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection: | x1/4, x1/2, x1, x2, x4, Auto |
Pacemaker detection: | Yes |
Protection: | Against electrosurgical interference and defibrillation |
► More Services
In addition to the sales of medical equipment, accessories and maintenance accessories, we also specialize in the maintenance of such machines and modules. As we are proficient in the maintenance of hospital equipment, we are good at renovating damaged machines and accessories. Therefore, if you have such machines or modules for maintenance, you can contact us and send them to us, and we will repair them at the fastest speed. But it is important to note that you must make sure that the items to be serviced are not opened and never serviced. Otherwise, it is unacceptable to us. Finally, please check your items carefully before sending them out.
Looking forward to receiving your early inquiry about PHiliphh Goldway UT6000A Patient Monitor ECG Board C-ECG7131C v1. Thank you for your time!
Contact Person: Bella
Tel: 86-18879075074