MS-2011 GE Carescape V100 Patient Monitor parts Masima Spo2 Board
Product Details:
Brand Name: GE
Model Number: MS-2011
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: MS-2011 GE Carescape V100 Patient Monitor Masima Spo2 Board Brand: GE
Part No: MS-2011 Application: GE Carescape V100 Patient Monitor
MOQ: One Piece Warranty: 90 Days
Condition: Work In Good Delivery Time: 3-5 Working Days
Delivery Method: DHL,UPS ,Fedex Payment Terms: Full Before Shipment
Highlight:

GE Carescape V100 Patient Monitor Parts

,

Masima Spo2 Board Patient Monitor Parts

MS-2011 GE Carescape V100 Patient Monitor Masima Spo2 Board

 

 

About SpO2 parameter 

 

The SpO2 parameter is suitable for continuous, non-invasive monitoring of functional oxygen saturation and provides pulse rate data as part of the CARESCAPE V100 vital signs monitor. Unless otherwise stated, this device is not designed, sold or intended for use.

 

 

The V100 monitor's SpO2 settings are available with three different cutting-edge technologies: Ohmeda TruSignal, Nellcor and Masima SET. Check the front of the monitor to see what SpO2 technology the monitor includes. If the monitor includes this setting, the SpO2 Technology logo is located on the front of the monitor.

 

The V100 monitor uses Masima SET pulse oximetry technology for continuous, non-invasive monitoring of functional oxygen saturation (SpO2) of arterial blood. Functional SpO2 is the ratio between oxygenated hemoglobin and hemoglobin capable of transporting oxygen. This ratio is expressed as a percentage and is displayed in the SpO2 window and is constantly updated.

 

Heart rate relative to SpO2 is displayed in the heart rate window. The sounds are emitted at a frequency corresponding to the pulse rate and at a pitch corresponding to the SpO2 saturation. The pitch is highest at 100% oxygen saturation and decreases as saturation decreases. The monitor displays a pulse amplitude bar. A bar graph of pulse amplitude is proportional to arterial blood flow.

 

 

This setting is automatically enabled when the sensor is connected to the display. Audible and visual alarms sound when SpO2 exceeds alarm limits. In the case of a parameter status alarm code, an alarm message is displayed in the SpO2 window.

 

 

SpO2 related configuration settings

 

There are three configuration settings for this parameter: averaging time (n0d), FastSAT (Sat), and sensitivity mode (Sen). Averaging time (n0d) allows you to select the number of seconds to average SpO2 data. Choose between 4 and 16 in steps of 2 (the alarm is delayed by this amount).

 

 

For FastSAT (Saturday), you can select 0 (off) or 1 (on). If FastSAT is set to 1 (enabled), SpO2 values are calculated faster. The Sensitivity Mode (Sen) parameter allows you to set the threshold value for calculating SpO2 values under low perfusion conditions. Select 1 (Maximized Low Perfusion), 2 (Low Perfusion - Standard), or 3 (Adaptive Probe Disabled).

 

 

 

SpO2 related buttons

 

There are no buttons associated with this setting.

 

SpO2 related windows

There is a window for this parameter: SpO2. In offline mode, nothing is displayed in the SpO2 window. In sleep mode, when the setting detects that the sensor is connected, a dash (-) will appear in the window. In mode and settings display valid data, the derived SpO2 values are displayed in this window and are continually updated. Values are displayed in %

 

 

 

Product Name

GE Carescape V100 patient monitor Masima spo2 board MS-2011

 

Brand GE
Part No MS-2011
Application GE Carescape V100 patient monitor
MOQ One piece
Warranty 90 days

 

MS-2011 GE Carescape V100 Patient Monitor parts Masima Spo2 Board 0

 

Thank you so much for your attention .If you're interested in MS-2011 GE Carescape V100 Patient Monitor Masima Spo2 Board ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.