China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | PHiliph |
Model Number: | GSI 600-23100-16 XE-50A |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | Printer Recorder GSI 600-23100-16 XE-50A For PHiliph MP20 MP30 Patient Monitor | Brand: | PHiliph |
---|---|---|---|
Part No: | GSI 600-23100-16 XE-50A | Application: | PHiliph MP20 MP30 Patient Monitor |
MOQ: | One Piece | Warranty: | 90 Days |
Condition: | Work In Good | Delivery Time: | 3-5 Working Days |
Delivery Method: | DHL,UPS ,Fedex | Payment Terms: | Full Before Shipment |
Highlight: | XE-50A Printer Recorder,GSI 600-23100-16 Printer Recorder,MP30 Patient Monitor Printer Recorder |
Printer Recorder GSI 600-23100-16 XE-50A For PHiliphh MP20 MP30 Patient Monitor
PHiliphh MP20 MP30 Patient Monitor Printer Recorder GSI 600-23100-16 XE-50A
About PHiliphh MP20 MP30 Patient Monitor Printer Recorder GSI 600-23100-16 XE-50A
PHiliphh MP20 and MP30 patient monitors are medical devices used to monitor vital signs and other patient data. Both models include a printer-recorder feature that makes it easy to record patient information.
Printer recorders allow medical professionals to obtain hard copies of patient data, including vital signs such as blood pressure, heart rate, oxygen saturation, and respiratory rate. This important feature allows medical staff to easily view and share patient information.
Printer Troubleshooting
Symptoms | Cause of Failure | Failure Isolation and Remedy |
Prompt message “Print job could not be queued” is issued. No print device is found. | Printer is disabled in the Setup Printers menu Paper size of printer does not match paper size of report | Enable the correct printer in the Setup Printers menu Change paper size of the printer in the Setup Printers menu or change paper size of the report in the Setup Reports menu. |
Status message “Print device Local 1 (Local 2) unavailable” is issued. Pr | Printer not switched on Printer paper tray empty Cabling not connected correctly PS/2 or USB I/O board defective | Switch on printer power fill printer paper tray Check cabling replace I/O board |
Status message “Print device Remote 1 (Remote 2, Remote 3) unavailable” is issued. Printer job is stalled | Print error on PHiliphh Information Center Network Connection to PHiliphh Information Center not functioning | Print a test report on the PHiliphh Information center. If this fails, refer to PHiliphh Information Center documentation Check that the network connection between the monitor and the PHiliphh Information Center is working |
Status message “Printing on device Remote 1... (Remote 2, Remote 3)” is issued but no report is printed | Print queue on PHiliphh Information Center is full. Reasons for this may be: - Printer is not switched on - Printer paper tray is empty |
Switch on printer power Fill printer paper tray
Configure the paper size according to the inserted print media Configure the printer resolution according to the printer capabilities Configure the printer color support to “Off” Check specifications |
Printouts are not as expected | Printer paper size is not correctly configured Printer resolution is not correctly configured Printer color support is configured to “On” although the printer does not support color Printer not compatible |
Thank you so much for your attention .If you're interested in Printer Recorder GSI 600-23100-16 XE-50A For PHiliphh MP20 MP30 Patient Monitor ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217