China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | PHiliph |
Model Number: | M2734A M2734B M2735A M2736A |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | PHiliph FM20 FM30 Fetal Monitor | Type: | M2705-66410 |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | Green | Power Consumption: | 110V—240v |
Power Source: | Electric | Feature: | User-friendly,Durable |
Business Purposes: | Advanced Technology, High-quality Products, Attentive Service | Mode Of Transport: | Expressage |
Inventory: | Available Now | Minimum Purchase Commitments: | 1unit |
Dominant Position: | Technical Engineers With 12 Years Of Experience | Condition: | In Good Form |
Sale Protection: | If There Are Any Problems Caused By Us, We Will Be Free For You To Repair Or Returned | ||
Highlight: | PHiliph FM20 Fetal Monitor Mainboard,M2705-66410 Fetal Monitor Mainboard,M2703-66510 Fetal Monitor Motherboard |
PHiliphh FM20 Fetal Monitor Mainboard Mother Board Main CPU Board M2705-66410 M2703-66510 0647 FT132
► Brief Introduction
PHiliphh Avalon FM20 FM30 Antepartum Monitor for attentive care and reassurance before childbirth and multiples monitoring capability
The Main CPU Board controls the monitor’s human interface, and is responsible for the final processing of data from the Bus Master Board. It sends this data to the TFT display, and to the thermal printer unit for recording traces and other patient data. It also controls the optional LAN/RS232 and PS/2 interface boards.
► Feature
► Specification
Signal Range | 0 – 127 Units |
Maximum Offset Range | -300 units |
Baseline Setting | 20 units |
Auto Offset Correction | 3 seconds after connecting the transducer, the Toco value is set to 20 units |
Auto Zero Adjust | Toco value is set to zero following a negative measurement value for 5 seconds |
► Removing the Main CPU Board
To remove the main CPU board, proceed as follows:
1 Remove the top cover assembly.
2 Remove the screws holding the metal shield
PHiliphh Avalon FM20 FM30 Antepartum Monitor for attentive care and reassurance before childbirth and multiples monitoring capability
The Main CPU Board controls the monitor’s human interface, and is responsible for the final processing of data from the Bus Master Board. It sends this data to the TFT display, and to the thermal printer unit for recording traces and other patient data. It also controls the optional LAN/RS232 and PS/2 interface boards.
► Feature
Touch screen with intuitive user interface for ease of use.
Large numeric displays ease readability.
User-confi gured notes for standardization of patient data and documentation.
Cross Channel Verifi cation, a PHiliphh safety feature, reduces the risk of confusing maternal and fetal heart rate signals. Cross Channel Verifi cation alerts when more than one heart rate channel processes the heart rate signal from the same source.
Audible alert of fetal bradycardia and tachycardia for advance warning of changes in fetal condition.
Built-in thermal paper recorder provides documentation of fetal traces and maternal parameters, together with user-defi ned annotations on an effi cient and easy to read documentation quality 15.2cm (6˝) paper strip. The recorder can also be set to run at high speed to record a 6 second maternal ECG strip in real time
Compact design is easy to move if needed, and screen folds down for wall mounting
► Specification
Signal Range | 0 – 127 Units |
Maximum Offset Range | -300 units |
Baseline Setting | 20 units |
Auto Offset Correction | 3 seconds after connecting the transducer, the Toco value is set to 20 units |
Auto Zero Adjust | Toco value is set to zero following a negative measurement value for 5 seconds |
► Removing the Main CPU Board
To remove the main CPU board, proceed as follows:
1 Remove the top cover assembly.
2 Remove the screws holding the metal shield
3 Remove the shield.
4 Disconnect the loudspeaker cable (1), the power supply cable (2), the bus master board cable (3), and the noninvasive blood pressure cable (4) from the main CPU board.
5 Remove the main CPU board by lifting it straight up.
f you want to explore more details about PHiliphh FM20 Fetal Monitor Mainboard Mother Board Main CPU Board M2705-66410 M2703-66510 0647 FT132, please let us know. Thank you for your time and interest. If you are interested in our products, welcome to place your orders. Early order early shipment!
Contact Person: Bella
Tel: 86-18879075074