Product Name: | 050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb And Light Board | Brand: | Mindray |
---|---|---|---|
Part No: | 050-002275-01 | Use For: | Mindary BeneVision N17 Patient Monitor |
Condition: | Work In Good | Warranty: | 90 Days |
MOQ: | One Piece | Delivery Time: | 3-5 Working Days |
Delivery Method: | DHL,UPS ,Fedex | Packaging: | Standard |
Highlight: | Alarm LED Bulb Patient Monitor Parts,050-002275-01 Patient Monitor Parts |
050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb and Light Board
Alarm LAMP Board
Alarm LAMP Board board is equipped with LED alarm light and light sensor. The light sensor detects the ambient light and adjusts the brightness
of the background light of the LCD.
Alarm Failures
Failure Description | Possible Cause | Troubleshooting |
Alarm LED goes off or fails to turn off when audible alarm sounds | Cable defective or improperly connected |
n1. Check whether the cable connecting the alarm light board and the main control board is connected correctly. n 2. Confirm that the connecting cables and connectors are not damaged |
Alarm LED board failure | Replace the alarm LED board. | |
Main control board failure | Replace the main control board. | |
There is no audible alarm when the alarm LED is normal | Audible alarm disabled | Select the Main Menu quick key, from the System column, select Maintenance → enter required password → select Alarm, set Minimum Alarm Volume to a proper value. Select the Main Menu quick key, from the Alarm column, select Setup, adjust the alarm volume to a proper value. |
Speaker failure | Replace the speaker. | |
Cable defective or improperly connected | Verify the cable connecting the speaker to the main control board is properly connected. | |
Main control board failure | Replace the main control board. |
Removing the Alarm Lamp and Light Sensor Board
1. Remove the cable on the alarm lamp and light sensor board.
2. Remove the two PT3×8 screws and take out the alarm lamp and light sensor board
NOTE
Alarm category
The monitor has two different types of alarms: physiological alarms and technical alarms.
■ Physiological alarms are triggered by patient measurements that exceed parameter limits or patient conditions that are abnormal.
■ Technical alarms are triggered by failure of electrical, mechanical or other monitors, or failure of sensors or components. A technical alarm condition may also result when the algorithm is unable to classify or interpret the available data. In addition to physiological and technical alarms, information can be prompted to inform the status of the system or the status of the patient.
Adjusting the Alarm Light Brightness
NOTE:
If you set alarm light brightness to Auto, the monitor automatically adjusts the alarm light brightness according to the ambient light. The stronger
the ambient light is, the brighter the alarm light is.