Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01

  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
  • Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01
Product Details:
Brand Name: Mindray
Model Number: 050-002275-01
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: 050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb And Light Board Brand: Mindray
Part No: 050-002275-01 Use For: Mindary BeneVision N17 Patient Monitor
Condition: Work In Good Warranty: 90 Days
MOQ: One Piece Delivery Time: 3-5 Working Days
Delivery Method: DHL,UPS ,Fedex Packaging: Standard
Highlight:

Alarm LED Bulb Patient Monitor Parts

,

050-002275-01 Patient Monitor Parts

050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb and Light Board

 

 

Alarm LAMP Board

Alarm LAMP Board board is equipped with LED alarm light and light sensor. The light sensor detects the ambient light and adjusts the brightness

 

of the background light of the LCD.

 

 

Alarm Failures

 

 

Failure Description Possible Cause Troubleshooting
Alarm LED goes off or fails to turn off when audible alarm sounds Cable defective or improperly connected

n1. Check whether the cable connecting the alarm light board and the main control board is connected correctly. n

2. Confirm that the connecting cables and connectors are not damaged

Alarm LED board failure Replace the alarm LED board.
Main control board failure Replace the main control board.
There is no audible alarm when the alarm LED is normal Audible alarm disabled Select the Main Menu quick key, from the System column, select Maintenance → enter required password → select Alarm, set Minimum Alarm Volume to a proper value. Select the Main Menu quick key, from the Alarm column, select Setup, adjust the alarm volume to a proper value.
Speaker failure Replace the speaker.
Cable defective or improperly connected Verify the cable connecting the speaker to the main control board is properly connected.
Main control board failure Replace the main control board.

 

 

 

 

 

Removing the Alarm Lamp and Light Sensor Board

 

1. Remove the cable on the alarm lamp and light sensor board.

 

2. Remove the two PT3×8 screws and take out the alarm lamp and light sensor board

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01 0

 

 

NOTE

  • Be careful when disconnecting the cable to avoid damage. 
  •  
  • When installing, align the positioning ribs of the front shell plate, and press the plate towards the direction of the alarm light cover. 
  •  
  • When reinstalling the board, be careful to avoid overtightening the screws and stripping the holes.

 

Alarm category

 

The monitor has two different types of alarms: physiological alarms and technical alarms.

 

■ Physiological alarms are triggered by patient measurements that exceed parameter limits or patient conditions that are abnormal.

 

■ Technical alarms are triggered by failure of electrical, mechanical or other monitors, or failure of sensors or components. A technical alarm condition may also result when the algorithm is unable to classify or interpret the available data. In addition to physiological and technical alarms, information can be prompted to inform the status of the system or the status of the patient.

 

 

 

Adjusting the Alarm Light Brightness

 

NOTE:

If you set alarm light brightness to Auto, the monitor automatically adjusts the alarm light brightness according to the ambient light. The stronger

 

the ambient light is, the brighter the alarm light is.

 

Mindary BeneVision N17 Patient Monitor parts Alarm LED Bulb And Light Board 050-002275-01 1

 

Thank you so much for your attention .If you're interested in 050-002275-01 Mindary BeneVision N17 Patient Monitor Alarm LED Bulb and Light Board,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.