China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Welch Allyn |
Model Number: | 030-0098-05 REV B |
Minimum Order Quantity: | One piece |
---|---|
Packaging Details: | Standard |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western ,Paypal |
Product Name: | 030-0098-05 REV B Welch Allyn Vital Signs Monitor 300 Series 53NTP VSM III Main PCB Board | Brand: | Welch Allyn |
---|---|---|---|
Part No: | 030-0098-05 REV B | Use For: | Welch Allyn Vital Signs Monitor 300 Series 53NTP |
MOQ: | One Piece | Warranty: | 90 Days |
Condition: | Work In Good Condition | Packaging: | Standard |
Delivery Time: | 3-5 Working Days | Delivery Method: | DHL ,Fedex ,UPS |
Highlight: | 030-0098-05 Vital Signs Monitor,53NTP Vital Signs Monitor,Vital Signs Monitor Main PCB Board |
030-0098-05 REV B Welch Allyn Vital Signs Monitor 300 Series 53NTP VSM III Main PCB Board
About Welch Allyn Vital Signs Monitor 300 Series 53NTP
The monitor can monitor systolic and diastolic non-invasive blood pressure (NIBP), heart rate and MAP (mean arterial pressure). Units configured
with the appropriate options can also monitor temperature and SpO2 simultaneously and continuously monitor heart rate. All vital signs readings
are displayed on the front panel of the monitor. These measurements can also be printed using the optional integrated thermal printer. The
monitor offers programmable audio and visual alarms and automatic NIBP measurement at selected intervals. It can also be configured to provide
an alarm-activated nurse call function.
Other equipment connected to the analog and digital interfaces must be certified in accordance with applicable IEC standards (IEC 60950 for data
processing equipment, IEC 60601-1 for medical devices). All these provisions must comply with the system standard IEC 60601-1-1.
Remove the main board
Main board reassembly notes
Caution
Take care when reconnecting the main board power connector (J3). If the cable connector is connected improperly, the monitor could be damaged when power is applied.
Older main boards (version 031-0150-01)
To reconnect the main board power connector (J3), be certain that the cable connector is oriented with the slotted side up...
Newer main boards (versions 031-0150-03 and -04)
Product Name |
Welch Allyn Vital Signs Monitor 300 Series 53NTP VSM III main PCB board 030-0098-05 REV B
|
Brand | Welch Allyn |
Part No |
030-0098-05 REV B
|
Use for | Welch Allyn Vital Signs Monitor 300 Series 53NTP |
MOQ | One piece |
Thank you so much for your attention .If you're interested in 030-0098-05 REV B Welch Allyn Vital Signs Monitor 300 Series 53NTP VSM III Main PCB Board ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217