Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc

Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc

  • Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
  • Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
  • Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
  • Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
  • Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc
Product Details:
Brand Name: Masima
Model Number: 1863
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD
Packaging Details: Standard Export Packing
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union, Paypal
Contact Now
Detailed Product Description
Brand: Masima REF: 1863
Product Category: SpO2 Product Type: Sensor
Length: 3 Ft Applicable Site: Fingers
Line Color: White Applicable Patient: Adult
Recommended Weight: >30Kg Use: Reusable
High Light:

Adult Finger Clip SpO2 Sensor

,

REF1863 Finger Clip SpO2 Sensor

Masima LNCS DCI Reusable Sensor

Masima LNCS DCI 9pin Adult Finger clip SpO2 Reusable Sensor REF 1863

Brief Description

The primary function of the Masima 1863 LNCS DCI 9-pin Adult Finger clip SpO2 Reusable Sensor is "spot check" or continuous noninvasive monitoring of a patient's arterial hemoglobin functional oxygen saturation (SpO2) and pulse rate (as measured by the SpO2 sensor). The SpO2 Reusable Sensor is applicable to a wide range of people, as long as it is an adult or a child with a body weight of more than 30kg. However, patients under this weight are not recommended to use the SpO2 Reusable Sensor to avoid unnecessary accidents.

 

 

 

Specification

Product Category SpO2
Product Type Sensor
Total Length 3 ft
Applicable Site Fingers
Recommended Weight >30Kg
REF 1863

 

 

 

► Caution

Before using it on patients, the first choice of medical personnel is generally the non-dominant part of the patient, such as the non-dominant ring finger, including fingers and toes. However, before connecting the sensor to the patient, a necessary step is to clean the remnants of the patient's monitoring site. Only after cleaning can the sensor be placed, so as not to cause inaccurate readings and other effects. Before use, medical personnel must carefully check whether the surface of the sensor or the core wire is damaged, and confirm whether there are damaged parts. Once any damaged part is found, stop using it immediately, otherwise it will affect the reading accuracy of the sensor, and even affect the life safety and health of the patient.

 

 

 

Precautions

When using Masima 1863 LNCS DCI Reusable Sensor, medical personnel must check the patient's monitoring site frequently or according to the patient's actual situation and needs to ensure that the blood circulation of the patient's monitoring site is normal, the skin is intact, and the sensor is optically calibrated correctly. Skin ulceration, tissue ischemia, and/or compressive necrosis at the patient's monitoring site may result if the sensor is not moved frequently, if the sensor is attached too tightly, or becomes too tight at the patient's monitoring site due to patient edema. If there is damage to the skin and/or poor circulation or hypoperfusion once the patient monitors the site, the sensor should be moved. Therefore, when using the sensor, the sensor should be moved frequently and the monitoring site should be changed, usually once an hour, and if necessary, it should be changed according to the actual situation of the patient.

 

 

 

Detailed photos

Masima LNCS DCI 9 Pin Adult Finger Clip SpO2 Sensor REF 1863 For Hospital ICU Clinc 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thank you for your time. If you are interested in our company or our Masima LNCS DCI 9pin Adult Finger clip SpO2 Reusable Sensor REF 1863, or have any suggestions for us, please feel free to contact us. We will reply you within 12 hours. Wish you a happy life.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Jasmine

Tel: 86-15180047496

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.