China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Hamilton C2 ventilator Battery |
Model Number: | 369106 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Hamilton C2 Ventilator Battery | Type: | 369106 |
---|---|---|---|
Warranty: | 90days | Color: | Black |
Index Terms: | Battery | Function: | Provide Power For Oxygen Concentrator L |
State: | Working Fine | Nominal Voltage: | 14.4v 6.6Ah 97Wh |
Inventory: | In Stock | Minimum Purchase Contract: | 1pcs |
Mode Of Transport: | Expressage | Voltage: | 12.0 To 16.8VDC |
Type:: | Lithium-ion, | Recharge Time: | 4 H Minimum |
Storage:: | -20 To 60 °C, 95% Relative Humidity | ||
Highlight: | Hamilton C2 Ventilator Battery,Ventilator Battery 6.6Ah,REF 369106 Ventilator Battery |
► Brief Introduction
HAMILTON MEDICAL recommends that the ventilator’s batteries be fully charged before you ventilate a patient. If the batteries are not fully charged and AC power fails, always pay close attention to the level of battery charge.
Two backup batteries, one standard and the other optional, protect the HAMILTON-C2 from low, or failure of, the primary power source. When the primary power source (either AC mains or a DC power supply) fails, the ventilator automatically switches to operation on backup battery with no interruption in ventilation. An alarm sounds to signal the switchover. You must silence the alarm to confirm notification of the power system change; this resets the alarm. If the optional battery (battery 2) is available and adequately charged, the ventilator switches to this battery first. When battery 2 is depleted or not installed, the ventilator switches to the standard battery (battery 1). The batteries power the ventilator until the primary power source is again adequate or until the battery is depleted. Each battery powers the ventilator typically for 2.5 h.
As a further safeguard, the HAMILTON-C2 provides a low battery alarm. It also has a capacitor-driven backup buzzer that sounds continuously for at least 2 min when battery power is completely lost.
► Specification
Type: | Lithium-ion, |
Recharge time | 4 h minimum |
Storage: | -20 to 60 °C, £ 95% relative humidity |
► Replacing the batteries
Open the battery door (3). To remove battery 1 (1), turn the retaining screw until the battery is released. To remove battery 2 (2), press on the tab, and slide the battery out of its housing. Replace with a newly charged battery.
• To ensure that the ventilator always has battery backup, keep locked battery 1 in the ventilator at all times during ventilator operation. Battery 2 may be hot swapped while the ventilator is operating.
• Because of damage of the battery door lock the batteries in the correct position.
1 Battery 1
2 Battery 2
3 Door
► Warm Tips
In order to avoid causing unnecessary trouble, please read the following carefully.
Please look through all the pictures with patience before placing orders to confirm the product is exactly you want or not as they are also an important part of the product description. What’s more, it is buyer’s responsibility to pay for all the customs fees including all taxes and duties. So it is of great necessity for you to make certain that the equipment you are ordering can be imported in to your country. Once the package leaves our factory, the shipper is not responsible for any delays any more. So please keep it in mind that be sure to check out all the relevant information before placing your orders.
If you have any questions about Hamilton C2 ventilator Battery 14.4v 6.6Ah 97Wh Lithium Ion Battery REF 369106 , please feel free to contact us at any time, we are glad to answer them.
Contact Person: Bella
Tel: 86-18879075074