Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door

  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
  • 453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door
Product Details:
Brand Name: philip
Model Number: MX40
Payment & Shipping Terms:
Minimum Order Quantity: one piece
Packaging Details: Carton
Payment Terms: T/T(Bank Wire ),Paypal ,Western union
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Product Name: 453564602631 Philip MX40 Patient Monitor Battery Compartment Door
Brand: Philip Part No: 453564602631
Use For: Philip MX40 Patient Monitor Condition: Used
MOQ: One Piece Warranty: 90 Days
Material: Plastic Delivery Method: DHL ,Fedex UPS Etc
High Light:

philip MX40 Patient Monitor Parts

,

453564602631 Patient Monitor Parts

philip MX40 Patient monitor battery compartment door 453564602631

 

The battery compartment door is located on the back of the MX40, accessible from the bottom by opening the battery compartment door. It holds three AA 1.5V alkaline batteries or philip rechargeable Li-ion batteries.

 

Inserting Battery

1.Open the battery compartment by lifting up on both bottom sides of the compartment door.

 

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door 0

2.Remove the AA battery tray if present.

 

 

3.Insert the battery pack so that the raised tab is aligned with the cutout in the base of the battery compartment.

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door 1

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door 2

4.Close the battery compartment door.

 

453564602631 philip MX40 Patient Monitor Battery Compartment Door  Specification 

 

Product Name

philip MX40 Patient monitor battery compartment door 453564602631 Inserting Battery

 

Brand philip
Part NO 453564602631
Material Plastic

 

 

battery safety information

 

The battery compartment door must be closed during defibrillation.

 

 

Use a rechargeable philip Li-ion battery or three Duracell AA, MN 1500, 1.5V alkaline batteries to ensure the listed performance and correct battery indicator reporting. Old, incompatible, or poor quality batteries may provide unacceptable performance (e.g. low battery warning times). It is highly recommended to use new high quality alkaline batteries.

 

 

Some abnormal conditions, such as short circuits, may cause the battery to overheat during use. High temperatures can cause patient and/or user burns if the MX40 becomes hot to the touch. Remove from patient and set aside until cool. Then remove the battery and discard it. Have the MX40 checked by your service provider to determine the cause of the overheating.

 

 

If you receive a TELE BATTERY LOW, TELE BATTERY EMPTY, REPLACE BATTERY T, or TELE BATTERY TEMP warning, the battery should be replaced immediately. Failure to change these conditions will cause the device to shut down and the check to end.

 

 

Disposable batteries should be removed from the MX40 at the end of its life to prevent leakage. If the battery leaks Be careful when removing the battery. Released material may cause eye or skin irritation. Avoid contact with the skin. Clean the battery compartment according to the care instructions. Wash your hands.

 

 

 

To reduce the risk of electric shock or fire Do not carry batteries loose, such as in a pocket.

 

 

 

453564602631 philip MX40 Patient Monitor Parts Battery Compartment Door 3

 

 

 

Caution

The use of AA lithium batteries or batteries with a polarity voltage > 1.6 V may damage the device.

When tested with the MX40 WLAN version (model 865352), the rechargeable Li-ion battery is the only approved power source. The use of disposable AA batteries is not supported.

 

 

If you're interested in 453564602631 philip MX40 Patient Monitor Battery Compartment Door ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.