PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521

PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521

  • PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521
  • PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521
  • PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521
  • PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521
PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521
Product Details:
Brand Name: PHiliph Goldway
Model Number: GCF1203 989803177521
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: PHiliph Goldway G And UT Series NIBP Cuff Type: GCF1203 989803177521
Application: Patient Monitor Warranty: 90days
Color: Gray Functions: Monitor Patient's Health Condition,Print Electrocardiogram
Usages: ICU, Emergency, Patient Monitor, ICU Room And Operating Room Measurement Site: Arm
After-sale Service: If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned Limb Circumference (cm): 25-35cm
Management Principles: Advanced Technology, High-quality Products, Attentive Service Condition: In Good Order
MEANS OF TRANSPORT: Expressage Systolic Adult/Pediatric: 30 ~ 254mmHg (4.0 ~ 33.9kPa)
Systolic Neomate: 30 ~ 135mmHg (4.0 ~ 18.0kPa) Diastolic Adult/Pediatric: 10 ~ 220mmHg (1.3 ~ 29.3kPa)
Diastolic Neomate: 10 ~ 110mmHg (1.3 ~ 14.7kPa)
Highlight:

GCF1203 989803177521

,

PHiliph Goldway Patient Monitor NIBP Cuff

,

Patient Monitor Parts NIBP Cuff

 

PHiliphh Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521

 

 

 

► Brief Introduction

NIBP processing uses an oscillometric technique to provide needed measurements at selected intervals. This technique uses an inflatable sphygmomanometer cuff similar to those used by clinicians in routine measurements. A motorized pump inflates the cuff to approximately 170 mmHg (adult mode) initially, at which point the pressure effectively stops the flow of blood. Then, under monitor control, the pressure in the cuff is gradually reduced, while a pressure transducer detects the pressure and transmits the parameter signal to the NIBP input circuitry. As the pressure is reduced, blood flows in the previously occluded artery, and changes the measurements made by the transducer. The point at which oscillation increases sharply is defined as systolic pressure. As the cuff continues to deflate, the oscillation amplitude increases to a maximum, and then decreases. The peak oscillation amplitude is defined as the mean arterial pressure. The point at which the system detects a rapid decrease in oscillation is defined as the diastolic pressure.

 

 

PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521 0

► NIBP Specifications

Measure Range Systolic Adult/Pediatric 30 ~ 254mmHg (4.0 ~ 33.9kPa)
Systolic Neomate 30 ~ 135mmHg (4.0 ~ 18.0kPa)
Diastolic Adult/Pediatric 10 ~ 220mmHg (1.3 ~ 29.3kPa)
Diastolic Neomate 10 ~ 110mmHg (1.3 ~ 14.7kPa)
Cuff Pressure Range Adult/Pediatric 0 ~ 280mmHg (0 ~ 37.3kPa)
Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
Initial Cuff Inflation Adult/Pediatric 170 ± 10mmHg (22.7 ± 1.3kPa)
Neonate 100 ± 10mmHg (16.0 ± 1.3kPa)

PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521 1

 

 

 

NIBP Test

  • Reference manometer (includes hand pump and valve), accuracy 0.2% of reading
  • Expansion chamber (volume 500 ml ±10%)
  • Piece of appropriate tubing

 

 

Cleaning the NIBP Cuffs

 

To clean the cuff:

  1. Remove the bag from inside the cuff.
  2. Clean the cuff in detergent (mild soap water) and air dry it.
  3. Check the cuff and tube.

To sterilize the cuff to avoid cross-infection:

1. Disinfect the cuff in an autoclave or immerse it into one of the following detergents: 70% isopropanol or 70% ethanol

 

To put the rubber inflation bag back into the cuff:

  1. Roll the bag from both ends in the direction of the tube.
  2. Insert the rolled bag from the tube side into the opening on the short side of the cuff.
  3. Push the tube through to the other side of the cuff.
  4. Hold the tube together with the cuff and shake the whole cuff until it reaches the bag.

PHiliph Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521 2

Kindly Reminder

Before placing orders, there are some important issues that need to be paid attention to. For the purpose of promoting the business, please read the following items with patience and carefully. Firstly, please be sure to keep in mind to look over all the pictures patiently before purchasing to ensure the product you’re browsing is exactly what you want to buy. It is of vital importance to do so because pictures are also significant references of the product description. Secondly, the buyer is responsible for all the customs fees including all taxes and duties. Therefore, you have to make sure the machine you are ordering can be imported into your country. In a word, don’t forget to check out all related information when placing your orders.

 

 

We seek for providing perfect service to the satisfaction of customers. Thank you for your time! If you are interested in PHiliphh Goldway G and UT Series NIBP Cuff Adult GCF1203 25-35cm 989803177521, welcome to place your orders. Early order early shipment!

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Bella

Tel: 86-18879075074

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.