OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine

OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine

  • OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
  • OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
  • OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
  • OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
  • OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine
Product Details:
Place of Origin: Japan
Brand Name: Olympus
Model Number: MAJ-901
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: OLYMPUS MAJ-901 Water Container For Endoscope Machine Brand: Olympus
Part No: MAJ-901 Total Length: 560mm
Tank Outer Diameter: 65mm Capacity: 250mL
Condition: Original New Warranty: 90 Days
MOQ: One Piece Packaging Unit: One Piece
Highlight:

Endoscope Machine Water Bottle Container

,

MAJ-901 Water Container

,

250ml Endoscope Machine Water Container

OLYMPUS MAJ-901 Water Container For Endoscope Machine

 

Installation of the water container

 

When using an endoscope used for water feeding via the light source, prepare the water container as shown in the “System chart” in the Appendix. Install the water container in the water container holder on the left side of the light source

OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine 0

 

Product Name OLYMPUS MAJ-901 Water Container For Endoscope Machine
Brand Olympus
Part No MAJ-901
Place of Origin Japan

OLYMPUS MAJ-901 Water Bottle Container For Endoscope Machine 1

Drive/Working Principle

This product is connected to the pressurized tube/water tube provided in the endoscope specified by our company, and the pressurized air from the air pump of the light source unit is used as the pressure source to send sterilized water to the end of the endoscope. tank.

 

possible use

The purpose of this product is to deliver water from the endoscope in combination with our specified light source unit and endoscope with air and water supply functions.

 

Usage method, etc.

 

1. Cleaning, disinfection and sterilization Clean, disinfect (or sterilize) according to the determined method.

2. Inject sterile water

(1) Pour sterilized water into the water supply tank until the specified water level is reached.

(2) Screw the cover onto the tank.

3. Connect to the scope

(1) When installing the water tank, hang the hook on the light source or the water tank receiver of the trolley designated by our company.

(2) When using the water tank, connect the installation interface within the range specified by our company.

 

 

4. Cleaning, Disinfection and Sterilization After use, remove the scope from the scope and clean, disinfect and sterilize in the same manner as Section 1.

 

Precautions for use, etc.

1. Be sure to regularly check the water tank, cover, water supply pipe, etc. for wear and damage before use, and replace if necessary.

2. Install the O-ring securely and tighten the cover. Air or water supply may not be available.

3. Do not drop the water tank or hit it hard. It is possible to damage the water tank and not be able to supply air and water.

4. Do not bend, twist or pull the tube excessively. There is a risk of damage to the pipes, making it impossible to supply air or water.

5. Be sure to hang the water tank containing the sterilizing water on the light source unit or the water tank receiver of the trolley.

6. Push the mounting base directly into the oscilloscope. Attaching the oscilloscope at a steep slope may damage the mounting base and oscilloscope base.

7. Do not forcibly bend, twist, pull or remove the water supply hose on the back of the cover. There is a risk that the water supply pipe will be damaged and no water will be supplied.

8. Follow the procedure to install and remove the mounting cover slowly and carefully. Forcibly installing or removing the oscilloscope may damage the connection part or the mounting base of the oscilloscope, resulting in failure to supply air or water.

9. Do not lower the water level of the mounting interface removed from the oscilloscope below the tank water level. 10. When using the water tank, pay attention to the sterile water level, and add sterile water if necessary. If the sterilization water level is lower than the minimum water level, water supply may not be available.

 

Important Notes

  • This product has not been cleaned, disinfected or sterilized before delivery. Use without cleaning and disinfection (or sterilization) may lead to infection. Before use, please clean, disinfect or sterilize in accordance with "Chapter 6 Maintenance of Instruction Manual".

 

  • The water supply tank should be cleaned and disinfected (or sterilized) by emptying the tank of sterile water at the end of the case for at least one day. Using a poorly maintained tank can lead to infection.

 

 

Other faults

Equipment damage or malfunction

 

adverse event

other adverse events

electric shock, infection

 

 

If you're interested in OLYMPUS MAJ-901 Water Container For Endoscope Machine ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.