Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Machine Parts

Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12

Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12

  • Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12
  • Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12
  • Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12
  • Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12
Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12
Product Details:
Brand Name: Edan
Model Number: 02.01.210119029
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Edan Type: 01.13.036621
Warranty: 90days Product Type: Lead Set
Single-Patient Use OR Multi-Patient Use: Multi-Patient Use Minimum Shelf Life: None
AfterSales: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New Company Objectives: Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price
Product Situation: In Good Condition Features Introduction: Easy To Use,Professional, Reliable
MEANS OF TRANSPORT: Expressage
High Light:

Edan Patient Monitors Limb Wires

,

Edan X8 ECG Limb Wires

,

Edan X10 1m ECG Cable

 

 

Edan ECG Limb wires Cable 5-Lead clip AHA 1M reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 for Edan X8 X10 X12 Patient Monitors

 

 

 

► Brief Introduction

This ECG Cable is 5-Lead clip and work for Edan X8 X10 X12 Patient Monitors.

CWT Technology HK Limited are supply new or second hand medical equipments, accessories and repair parts including patient monitor, defibrillator machine, ECG,EKG machine. We will inspected the equipment and parts by our engineers to make sure it complete and in good condition. We are a reliable manufacturer providing the best products and services for global customers. We want to be your trusted partner in the future. If you want to explore more or have any questions about us, please feel free to contact us.

 

 

 

► Specifications

Lead Mode 5 Electrodes: I, II, III, aVR, aVL, aVF, V
Electrode Standard AHA
Sweep 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth (-3dB) Diagnosis: 0.05 Hz to 150 Hz
Diagnosis 1: 0.05 Hz to 40 Hz
Monitor: 0.5 Hz to 40 Hz
Surgery: 1 Hz to 20 Hz
Enhanced: 2 Hz ~18 Hz
Customized: High-pass Filter and Low-pass Filter
Differential Input Impedance > 5 MΩ
Input Signal Range ±10 mV PP
Electrode Offset Potential Tolerance ±800 mV
Leakage Current of Patient < 10 μA
Scale Signal 1 mV PP, accuracy is ±5%
System Noise < 30 μVPP

Edan ECG Limb Wires Cable 5 Lead Clip AHA 1M Reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 For Edan X8 X10 X12 0

 

 

 

Frequency response:

Input a 5 Hz, 1 mV sine wave signal, and the output signal amplitude remains within the range of 71 % to 110 % at 0.67 Hz and 40 Hz.

Input a 1 Hz, 1.5 mV 200 ms triangular wave input signal, and the output shall be within 11.25 mm~15 mm.

Impulse response:

Displacement value: ≤ 0.1 mV

Slope: ≤ 0.3 mV/s following the end of the pulse.

 

 

 

QRS Detection Range

The detection range has exceeded the requirement described in the standard:

Width: 70 ms~120 ms for adult, 40 ms~120 ms for Pediatric/neonate.

Amplitude: 0.5 mv~5 mv

In adult mode, these two signals are not responded:

  1. when QRS amplitude of 0.15 mV or less is applied;
  2. when QRS duration of 10 ms and QRS amplitude of 1 mV or less is applied.

 

 

Contact us

In order to successfully conclude the transaction, please contact us in time if you have any questions. If you want to know more information about our company or products, or if you are unclear about our warranty period, or if you have any good suggestions for our products and services, you can contact us to raise them. In short, as long as you need us, we are happy to answer you. Thank you for your cooperation. forward to establishing a long-term good cooperative relationship with you.

 

 

 

Thank you for your time! If you are interested in Edan ECG Limb wires Cable 5-Lead clip AHA 1M reusable REF EL05NAGS1 IPN 01.13.036621 MPN01.13 for Edan X8 X10 X12  , welcome to place your orders. Early order early shipment! 

Looking forward to receiving your early inquiry.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.