Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Module

Mindray T5 T6 T8 Patient Monitor Module Sidestream Co2 Module

Mindray T5 T6 T8 Patient Monitor Module Sidestream Co2 Module

  • Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module
  • Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module
  • Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module
  • Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module
Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module
Product Details:
Brand Name: Mindray
Model Number: T5 T6 T8
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Contact Now
Detailed Product Description
Delivery Time: 3-5 Working Days Payment Terms: Full Before Shipment
Product Name: Mindray T5 T6 T8 Patient Monitor Sidestream Co2 Module Brand: Mindray
Use For: T5 T6 T8 Patient Monitor Condition: Used
MOQ: One Piece Warranty: 90 Days
Delivery Method: DHL,UPS ,Fedex ,etc Payment Method: T/T ,Paypal ,Western Union
Packing: Carton
High Light:

Mindray T8 Patient Monitor Module

,

Mindray T5 Patient Monitor Module

,

Sidestream Co2 Module

Mindray T5 T6 T8 Patient Monitor Sidestream Co2 Module

 

 

CO2 monitoring is a continuous, non-invasive technique that determines the concentration of CO2 in a patient's airways by measuring the absorption of specific wavelengths of infrared (IR) light. CO2 has its own absorption properties and the amount of light that passes through the gas probe depends on the measured CO2 concentration. When certain wavelengths of infrared light pass through a breathing gas sample, some of the infrared light is absorbed by CO2 molecules. A photodetector measures the amount of infrared light transmitted through the breathing gas sample. The CO2 concentration is calculated from the measured amount of IR light.

There are two ways to measure CO2 in a patient's airway:

1. Common measurements use a CO2 sensor connected to an airway adapter that connects directly to the patient's respiratory system.

2. Lateral Flow/Microflow Measurements Sample the patient's exhaled gas with a constant sample flow from the patient's airway and analyze it with a CO2 sensor built into the CO2 module.

The measure provides:

1. CO2 waveform

2. CO2 value at the end of expiration (EtCO2): CO2 value measured at the end of expiration.

3. Fraction of CO2 inhaled (FiCO2): the smallest CO2 value measured during inhalation.

4. Airway Respiration Rate (awRR): The number of breaths per minute, calculated from the CO2 waveform

 

Product Name Mindray T5 T6 T8 Patient monitor sidestream co2 module
Brand Mindray
Use for T5 T6 T8 Patient monitor
Use place Hospital Devices; Medical Care; ICU;
Warranty 90 days
Delivery Time 3-5 working days

 

Identifying CO2 Modules

From left to right are sidestream CO2 module, microstream CO2 module and mainstream CO2.

Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module 0

  1. Setup key to enter the CO2 setup menu
  2. Measure/standby
  3. Gas outlet
  4. Slot for CO2 watertrap
  5. Connector for sampling line
  6. Connector for CO2 transducer

 

Using a Sidestream CO2 Module

 

1.Connect the water collector to the module, and then connect the CO2 assembly as shown in the picture below.

Mindray T5 T6 T8 Patient Monitor Module  Sidestream Co2 Module 1

2. By default, the sidestream CO2 module is in measurement mode. After inserting the CO2 module, the [CO2 Startup] message will appear on the screen.

3. After the startup is complete, the CO2 module needs time to warm up to reach the operating temperature. The message [CO2 Sensor Warmup] is displayed. Measurement accuracy may be affected if CO2 measurements are performed during warm-up.

4. After the warm-up is complete, you can take a CO2 measurement.

 

Note

  • Do not use adult watertrap for newborns. Failure to follow this precaution could result in patient injury.
  • To extend the life of the collector and module, turn off the collector and place it in standby mode when CO2 monitoring is not needed.

 

 

 

Caution

  • The watertrap collects the condensate droplets on the sampling line and prevents them from entering the module. When the accumulated water reaches a certain amount, it must be drained so as not to block the airways.

 

  • The watertrap has a filter that prevents bacteria, water and secretions from entering the module. After long-term use, dust or other substances can affect the function of the filter or even block the airways. In this case, replace the water collector. It is recommended to replace the watertrap every two months or when leakage, damage or dirt is detected.

 

 

If you're interested in Mindray T5 T6 T8 Patient Monitor Sidestream Co2 Module ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.