Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh

philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh

  • philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh
  • philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh
  • philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh
  • philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh
philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh
Product Details:
Brand Name: philip
Certification: CE
Model Number: 989803196521
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: 989803196521 Philip IntelliVue X3 MX100 Patient Monitor Rechargeable Lithium Ion Battery 10.8V 2000mAh Brand: Philip
Part No: 989803196521 Condition: Original New
Technology: Lithium Ion Power: 10.8 Volt
Use With Philip Equipment: Use With Philip Equipment Single- Or Multi-patient Use: Multi-patient
Sterile Or Non-sterile: Non-sterile Rechargeable: Yes
Current: 2.0 A Use With Non-philip Equipment: No
Packaging: 1 Battery Package Weight: 183 Gram
Capacity: 21.6 Wh WxHxD: 69.6 X 72.3 X 21.6 Mm (2.7 X 2.8 X 0.8 Mm)
High Light:

MX100 Patient Monitor Accessories

,

989803196521 Patient Monitor Accessories

,

Patient Monitor Lithium Ion Battery

989803196521 philip IntelliVue X3 MX100 Patient monitor Rechargeable Lithium Ion Battery 10.8V 2000mAh

 

 

The battery is required for the operation of the monitor. The battery lifetime is 3 years from manufacturing date or 500 charge/discharge cycles

Rechargeable lithium-ion battery designed for use with the IntelliVue X3 and IntelliVue MX100 patient monitors. 10.8V/21.6 Wh. Max Charge Current: 2.0A, Max charge Voltage: 12.3V, SMBus 1.1 compliant. 1 each = 1 battery

 

 

Features

Technology Lithium ion
Power 10.8 volt
Use with philip equipment 867030 (IntelliVue X3), 867033 (IntelliVue MX100)
Single- or multi-patient use Multi-patient
Sterile or non-sterile Non-sterile
CE certified Yes
Rechargeable Yes
Current 2.0 A
Use with non-philip equipment No
Packaging 1 battery
Package weight 183 gram
Capacity 21.6 Wh
Battery Life Minimum 3 years after receipt of product or other factors. See Monitor IFU for further details.
WxHxD 69.6 x 72.3 x 21.6 mm (2.7 x 2.8 x 0.8 mm)
Temperature range

• Discharge 0–60°C (32–140°F)

• Charge 0–60°C (32–140°F)

• Storage and Transport: -20–65°C (-4–149°F)

Humidity range

• Operating: 15–90% Relative Humidity (RH)

• Storage and Transport: 5–95% Relative Humidity (RH)

Safety Complies with: UL 62133/IEC 62133
Electromagnetic compatibility Complies with the requirements for FCC Type B computing device, and EN 61000-4-2, and EN 61000-4-3
Communication standard Complies with the SMBus specifi cation v1.1

 

 

philip IntelliVue X3 MX100 Patient Monitor Accessories 989803196521 Lithium Ion Battery 10.8V 2000mAh 0

 

Storage

When storing the battery, make sure that the battery terminals do not come into contact with conductive substances such as metal objects. For long-term storage of the battery, it is recommended to store it in a cool place at 15 ° C (60 ° C) with a 20% to 40% charge. Storage of the battery in a cool place can slow down the aging process.

Do not store the battery at temperatures other than -20 ° C (-4 ° C) to 60 ° C (140 ° C).

 

Do not store the battery in direct sunlight. The stored battery should be partially charged to 20-40% capacity every 6 months. Must be fully charged before use.

Note: Prolonged storage of the battery at temperatures above 38 degrees Celsius (100 degrees Celsius) can significantly reduce the expected battery life.

 

Battery life management

 

The life of the lithium ion battery depends on the frequency and duration of use. With proper care, it has a lifespan of around 3 years or 500 charge / discharge cycles, whichever comes first. Furthermore, experience has shown that the cumulative stress of daily use increases failure rates as battery life increases. Therefore, it is recommended to replace the Li-ion batteries after 3 years or 500 charge / discharge cycles. The era of lithium-ion batteries began with manufacturing. Check the date of manufacture and the charge and discharge cycles.

1. Select the battery symbol on the patient monitor screen.

2. Select the appropriate battery eject button.

3. If necessary, select the battery eject button again to view the battery details. The screen displays the date of manufacture, the number of charge and discharge cycles and other data about the battery.

 

If you're interested in 989803196521 philip IntelliVue X3 MX100 Patient monitor Rechargeable Lithium Ion Battery 10.8V 2000mAh ,feel free to contact us .Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.