Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110

philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110

  • philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
  • philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
  • philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
  • philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
  • philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110
Product Details:
Brand Name: Philip
Model Number: M4735A XL
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip M4735A XL Defibrillator Type: High Voltage Board
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Temperature Operating: 0º C To 55ºC Temperature Storage: -20º To 70ºC
Humidity: Up To 95% Relative Humidity Altitude Operating: Up To 15,000 Ft.
Altitude Storage: Up To 15,000 Ft. AC Line Powered:: 100-240 VAC, 50/60 Hz, 1.5A (Class 1)
Battery Powered: 12 V Rechargeable, SLA
High Light:

Defibrillator Power PCA Board

,

M4735A PCA Board

,

M4735-60110 PCA Board

 

Hospital Medical Equipment Parts philip HeartStart XL M4735A defibrillator Power PCA Board With Pacer M4735-60110

 

 

 

►Brief Introduction

The Power PCA is located in the bottom case.

Control of defibrillation functions on the Power PCA, including:

a. Initiating a capacitor charge sequence.

b. Monitoring charge on capacitor.

c. Initiating a shock delivery sequence.

 

Control of pacing functions on the Power PCA, including:

a. Starting/stopping pacing.

b. Controlling Rate and Output as selected by user, and monitoring pacing current delivered.

 

 

Removal

1. Disconnect the Patient Connector from the Power PCA.

a. Disconnect the 9-pin connector; press on the latch to release.

b. Disconnect the two High Voltage spade connectors by pulling up with a needle nose pliers.

2. Disconnect the Battery PCA from the Power PCA.

a. Disconnect the large white 4-pin connector; press on the latch to release. This connector carries the four battery wires (two red, two black).

b. Disconnect the small 2-pin connector; press on the latch to release.

3. Disconnect the Power Supply.

a. Disconnect the 6-pin connector from the Power PCA; press on the latch to release. Note it only carries three wires.

b. Disconnect the 4-pin connector from the Power PCA; press on the latch to release.

4. Disconnect the Control PCA ribbon cable.

Disconnect the large ribbon cable from the Control PCA. Its other end should already be disconnected from the Control PCA.

philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110 0

5. Remove the Power PCA.

a. Remove the 6-T10 size screws from the Power PCA.

b. Pull the Power PCA up and guide it around the Patient Connector and the case post.

 

TIP: Lift the back edge of the PCA (nearest the Power Supply) first. Then guide the PCA out to the right to clear the Patient Connector and the case post, and lift the PCA clear of the case.

 

 

Replacement

1. Replace the Power PCA.

a. Ensure the shield is still in its proper position in the bottom case.

b. Guide the Power PCA into position under the Patient Connector.

c. Replace the six T10 screws and tighten.

philip HeartStart XL M4735A Defibrillator Power PCA Board With Pacer M4735-60110 1

2. Connect the Control PCA ribbon cable.

Connect the large ribbon cable. Its other end will still be disconnected from the Control PCA.

3. Connect the Power Supply.

a. Connect the 2-pin in-line connector to the Battery PCA; be sure it latches.

b. Connect the 6-pin connector to the Power PCA; be sure it latches.

c. Connect the 4-pin connector to the Power PCA; be sure it latches.

4. Connect the Battery PCA to the Power PCA.

a. Connect the 4-pin connector; be sure it latches.

b. Connect the small 2-pin connector; be sure it latches.

5. Connect the Patient Connector to the Power PCA.

a. Connect the 9-pin connector; be sure it latches.

b. Connect the two High Voltage spade connectors by pushing straight down with a needle nose pliers.

 

 

Noninvasive Pacing

Waveform: Monophasic Truncated Exponential
Current Pulse Amplitude: 10 mA to 200 mA (5 mA resolution);
accuracy 10 mA to 50 mA ± 5 mA, 50 mA to 200 mA ± 10%
Pulse Width: 20 ms with accuracy +0, -5 ms.
Rate: 30 ppm to 180 ppm (10 ppm increments); accuracy ± 1.5%.
Modes: Demand or Fixed Rate
Refractory Period: 340 msec (30 to 80 ppm); 240 msec (90 to 180 ppm).

 

 

Customer satisfaction. Our biggest pursuit! If you have any questions about philip HeartStart XL M4735A defibrillator Power PCA Board With Pacer M4735-60110, please feel free to contact us at any time, we are glad to answer them.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.