Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A

M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A

  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
  • M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A
Product Details:
Brand Name: philip
Model Number: M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Contact Now
Detailed Product Description
Payment Terms: Full Before Shipment Product Name: M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02 Philip HeartStart XL M4735A Defibrillator Mainboard CPU Board
Brand: Philip Part No: M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02
Condition: Used Color: Green
Warranty: 90 Days MOQ: One Piece
Payment Method: T/T ,Paypal ,Western Union Deliver Time: 3-5 Working Days
Deliver Method: DHL ,UPS ,Fedex Etc
High Light:

M4735-80202 Defibrillator CPU Board

,

M4735-17902 Defibrillator CPU Board

,

M4735-61202 Defibrillator CPU Board

M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A defibrillator mainboard CPU board

 

 

 

Controls problems

 

Symptom

One of the keys doesn’t respond correctly

 

Possible Causes

• Key failure.

• Keyscan PCA failure.

• Control PCA failure

 

 

Suggested solution

Diagnose as follows: In Diagnostic Mode, run Controls test and identify all unresponsive keys.

• Some keys don’t respond: Replace

1) Keyscan PCA

  • Control PCA
  • Bezel Assembly.

• All keys don’t respond: Replace

1) Keyscan PCA

2) Control PCA.

 

 

 

Symptom

More than one of the keys, or all of the keys, don’t respond correctly.

 

 

Possible Causes

• Keyscan PCA failure.

• Control PCA failure.

• Keypanel failure.

 

Suggested solution

Diagnose as follows: In Diagnostic Mode, run Controls test and identify all unresponsive keys.

• Some keys don’t respond: Replace

1)Keyscan PCA

2)Control PCA

3)Bezel Assembly.

• All keys don’t respond: Replace

1)Keyscan PCA

2) Control PCA.

 

 

 

Symptom

 

The Energy Select Switch doesn’t respond correctly.

 

 

Possible Causes

• Keyscan PCA failure.

• Control PCA failure.

• Switch failure.

 

Suggested solution

Diagnose as follows: In Diagnostic Mode, run Controls test and test Switch. • Some switch selections don’t respond: Replace

1) Switch

  • Control PCA
  • Keyscan PCA.

• All switch selections don’t respond: Replace

1) Keyscan PCA

2) Control PCA

3) Switch.

 

Item name

philip HeartStart XL M4735A defibrillator mainboard CPU board M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02 M4735-17903-A 00 05

 

Brand philip
Model M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02 M4735-17903-A 00 05
Use place Hospital Devices; Medical Care; ICU;
Deliver time 3-5 days
Warranty 90 days

 

M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A 0

 

 

Control PCA

The following steps describe how to remove and replace the PCA controller. The Control PCA includes operating software for the device, including the data necessary for voice commands.

 

Note: A language utility is not required to easily remove and replace the existing Control PCA.

 

Preparation

1. Save the configuration.

2. Open the case securely.

 

Removal

1. Disconnect the control PCA (5 wires).

a) Disconnect the large ribbon cable on the left side of the controller PCA.

b) Disconnect the small ribbon cable on the left side of the controller PCA (connected to parameter PCA).

c) Disconnect the small flat cable (attached to the printer) at the back of the PCA. To do this, release the latch at the end of the connector. Slide the latch to release it.

d) Disconnect the 2-wire mini-jack on the front of the PCA (speaker connection). There is a latch at the top of this connector. Press the latch to release it and move the connector from side to side to remove it.

e.) Disconnect the large ribbon cable on the right side of the Control PCA (connected to the Keyscan PCA).

 

M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A 1

2. Remove the screws.

A) Remove the eight screws around the control PCA edge.

b.) Remove the worm near the center of the PCA. Be careful not to damage nearby parts or routes.

 

3. Remove the control PCA.

 

A) Move the Control PCA back by removing the metal shield. It will help the button to remove its hole in the black plastic shield around the data card slot.

 

Note: Remove the black plastic cover if it is damaged. Otherwise, place it on a metal cover. If you replace Control PCA, The new PCA comes with a new plastic cover.

 

b) When PCA is returned for repair. Leave the lithium battery empty. This will help save factory troubleshooting information.

M4735-80202 Defibrillator Mainboard CPU Board M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A 2

Replacement

1. Place the control PCA.

Align the holes in the control PCA with the straps tied inside the cover. Lower the PCA area.

 

Note: Do not drag the PCA across the screen to adjust it.

 

2. Replace the screws.

Tip: It is easier to install the screws if all the screws are inserted into the holes before tightening.

3. Connect the control PCA.

A) Connect the speaker cables.

B) Connect the printer cable.

c.) Connect the PCA parameter tape.

D) Connect the tape to Keyscan PCA.

4. Replace the plastic cover if necessary.

If the black plastic cover has been damaged in the past, Replace it with the cover provided by the new Control PCA. Remove the rest of the old shield, tear off the protective sheet, and press firmly to hold the shield in place.

 

If you're interested in  M4735-80202 M4735-61202 M4735-17902 M4735-17901-A 00 02 philip HeartStart XL M4735A defibrillator mainboard CPU board ,feel free to contact us .Thank you .

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.