Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1

Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1

  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1
  • Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1
Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1
Product Details:
Brand Name: Nihon Kohden
Model Number: TEC-7621C
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Nihon Kohden Cardiolife Defibrillator Blood Pressure Plate Type: TEC-7621C
Application: Defibrillator Warranty: 90days
MOQ: 1pcs Inventory Situation: Sufficient Inventory
Apply For: Defibrillator Discharge Modes: Synchronous And Asynchronous
Measuring Range:: 0 To 300 MmHg Applications Scenes: ICU, Emergency, Patient Monitor, ICU Room And Operating Room
Measurement Mode:: Manual / STAT (continuous) / Automatic (periodic) Adult Upper Limit Range: 15 To 260 MmHg In 5 MmHg Steps, OFF
Adult Lower Limit Range: OFF, 10 To 255 MmHg In 5 MmHg Steps
High Light:

Defibrillator Blood Pressure Plate

,

Nihon Kohden Defibrillator Blood Pressure Plate

,

TEC-7621C Defibrillator Blood Pressure Plate

 

Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1

 

 

 

Brief Introduction

This Blood Pressure Plate is work for Nihon Kohden Cardiolife TEC-7621C Defibrillator.

CWT Technology HK Limited, located at Guangzhou, China. During these years of marketing and expanding, we have accumulated a great wealth of experience both in product distribution and customer service. We are a trust worthy medical equipment supplier as we have been engaged in this industry for so many years. Customer will received satisfactory goods.

We understand the importance of the concept of win-win cooperation, we commit ourselves to protect the medical equipment market, satisfying all the customers' demands is our permanent pursuit.

We are looking forward to establishing a long cooperative relationship with you.

 

 

NIBP Specifications

 

Parameter Specification
Display parameters Systolic pressure, mean pressure, diastolic pressure, cuff pressure
Measuring range: 0 to 300 mmHg
Accuracy: ±3 mmHg (0 mmHg ≤ NIBP < 200 mmHg)
±4 mmHg (200 mmHg ≤ NIBP ≤ 300 mmHg)
Measurement mode: Manual / STAT (continuous) / Automatic (periodic)

Alarm:

Adult

  • Upper limit range: 15 to 260 mmHg in 5 mmHg steps, OFF
  • Lower limit range: OFF, 10 to 255 mmHg in 5 mmHg steps

Neonate

  • Upper limit range: 10 to 125 mmHg in 5 mmHg steps, OFF
  • Lower limit range: OFF, 5 to 120 mmHg in 5 mmHg steps

Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1 0

 

NIBP Mesurement Troubleshooting

 

Message Possible Cause Action
NIBP air hose disconnected The air hose is disconnected from the NIBP socket. Connect the air hose properly. When NIBP monitoring is not necessary, press the SILENCE ALARM key to silence the alarm. The NIBP display can be cleared.
The air hose is damaged. Replace the air hose with a new one.
Faulty NIBP unit. Replace the NIBP unit.
NIBP air leak The cuff pressure does not change after inflation even after a certain period of time. Connect the cuff to the air hose properly.
Connect the air hose to the socket properly.
The cuff or air hose is damaged. Replace the cuff or air hose with a new one.
Faulty NIBP unit. Replace the NIBP unit.
NIBP measurement time out The measuring time exceeded the specified time due to arrhythmia or noise. If the cause is arrhythmia, measure by invasive blood pressure measurement. Remove the cause if due to noise.
Faulty NIBP unit. Replace the NIBP unit.
Faulty NIBP unit. Replace the NIBP unit.

 

 

 

 

Thank you for your time! If you are interested in Nihon Kohden Cardiolife TEC-7621C Defibrillator Blood Pressure Plate UR-0257 6190-022986A S1 , welcome to place your orders. Early order early shipment! If you want to explore more details please let us know.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.