Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable

Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable

  • Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable
  • Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable
  • Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable
  • Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable
Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable
Product Details:
Brand Name: Masima
Model Number: Rainbow RC-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Masima Patient Cable Type: Rainbow RC-12
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Color: Purple Power Supply Source: Electric
Rated Voltage: 110V — 240v Product Conditions: Running Sweetly
Product Characteristics: Professional, Reliable,Functional,Durable Post-sales Service: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New
Goodness: New And Original Supported Languages: English,French,Italian,Spanish,Japanese,Hindi,Portuguese,Russian,etc
Minimum Purchasing Quantity: 1 Pcs Delivery Terms: Express
Length: 12 Ft /3.7m
High Light:

Rainbow Patient Cable

,

Mindray Datascope Patient Cable

 

Masima Rainbow® Patient Cable Rainbow RC-12 for Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable

 

 

 

►Brief Introduction

Rainbow® RC-12 Patient Cable, 12 ft (3.7m) For use with rainbow and M-LNCS sensors.
It’s 8 pins, purple connector.
This Spo2 Cable is measure SpO2 on a healthy person’s finger and a Pleth wave and PR value are displayed. The displayed SpO2 value is within 95% and 100%.
The SpO2 value displayed on the monitor screen is the average of data collected within a specific time. The shorter the averaging time is, the quicker the patient monitor responds to changes in the patient’s oxygen saturation level. Contrarily, the longer the averaging time is, the slower the patient monitor responds to changes in the patient’s oxygen saturation level, but the measurement accuracy will be improved. For critically ill patients, selecting shorter averaging time will help understanding the patient’s state.

 

 

 

Setting SpO2 Sensitivity

For Masima SpO2 module, you can set [Sensitivity] to [Normal] or [Maximum] in the [SpO2 Setup] menu. When the [Sensitivity] is set to [Maximum], the patient monitor is more sensitive to minor signals. When monitoring critically ill patients whose pulsations are very weak, it is strongly recommended that the sensitivity is set to [Maximum]. When monitoring neonatal or non-critically ill patients who tend to move a lot, noise or invalid signals may be caused. In this case, it is recommended that the sensitivity is set to [Normal] so that the interference caused by motion can be filtered and therefore the measurement stability can be ensured.

Masima Rainbow® Patient Cable Rainbow RC-12 For Mindray Datascope DATASCOPE DPM6 DPM7 SPO2 Adapter Cable 0

 

 

SpO2 Specifications

Alarm limit Range (%) Step (%)
Desat 0 to (high limit – 1)
20 to (high limit – 1)
1

 

 

 

Masima SpO2 Module

Measurement range 1 to 100%
Resolution 1%
Refreshing rate 1 s
SpO2 averaging time 2-4 s, 4-6 s, 8 s, 10 s, 12 s, 14 s, 16 s
Low perfusion SpO2 accuracy ±2%
Low perfusion conditions Pulse amplitude: >0.02%
Light penetration: >5%
Accuracy 70 to 100%: ±2% (measured without motion in adult/pediatric mode)
70 to 100%: ±3% (measured without motion in neonate mode)
70 to 100%: ±3% (measured with motion)
0% to 69%: Not specified.

 

 

 

Measurement Limitations

If you doubt the measured SpO2, check patient vital signs first. Then check the patient monitor and SpO2 sensor. The following factors may influence the accuracy of measurement:

  • Ambient light
  • Philipilipysical movement (patient and imposed motion)
  • Diagnostic testing
  • Low perfusion
  • Electromagnetic interference, such as MRI environment
  • Electrosurgical units
  • Dysfunctional haemoglobin, such as carboxyhemoglobin (COHb)and methemoglobin (MetHb)
  • Presence of certain dyes, such as methylene and indigo carmine
  • Inappropriate positioning of the SpO2 sensor, or use of incorrect SpO2
  • Drop of arterial blood flow to immeaurable level caused by shock, anemia, low temperature or vasoconstrictor.

 

 

If you have any questions about Masima Rainbow® Patient Cable Rainbow RC-12 , please feel free to contact us at any time, we are glad to answer them. Looking forward to receiving your early inquiry. Thanks for Your Cooperation.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.