China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | PHiliph |
Model Number: | 989803149981 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | REF 989803149981 PHiliph FR3 AED Heartstart Pads III For Child Adult | Brand: | PHiliph |
---|---|---|---|
Part No.: | 989803149981 | Use With PHiliph Healthcare Equipment: | 861388, 861389 |
CE Certified: | Yes | Package Weight: | 0.091 Kg |
Packaging Unit: | 1 = 1 Set | Sterile OR Non-Sterile: | Non-Sterile |
Use With Non-PHiliph Healthcare Equipment: | NO | Product Type: | Pads |
Single-Patient Use OR Multi-Patient Use: | Single-Patient Use | Not Manufactured With Natural Rubber Latex: | Yes |
Minimum Shelf Life: | 30 Months From Date Of Manufacturing | Use With Other Supplies: | N/A |
Patient Application: | Child; Adult | Conductor Surface Area: | 80 Cm2 |
Temperature Range For Storage: | 0° - 50°C | Leadwire Length: | 1.2 M (3.9') |
Highlight: | 989803149981 Defibrillator Machine Parts,PHiliph FR3 Defibrillator Machine Parts |
REF 989803149981 PHiliphhilip FR3 AED Heartstart Pads III For Child Adult
SMART Pads III has been simplified for rapid deployment. The tedious step of unwrapping the swab at the beginning of the reaction can be eliminated. Plus, they can be used for both adults and children (with the optional baby/child key), so you don't have to waste time changing pillowcases. Offset labels allow for quick and easy use of peel and place workflows. When used with a PHiliphhilip FR3 carrying case with Sentry Pads, the SMART Pads III can be pre-connected and tested during the FR3 self-test routine. The versatile SMART Pads III connector is compatible with HeartStart manual defibrillators for ECG monitoring, external pacing, synchronized cardioversion, and defibrillation.
Specification
Use with PHiliphhilip Healthcare Equipment | 861388, 861389 |
CE Certified | Yes |
Package Weight | 0.091 kg |
Packaging Unit | 1 = 1 set |
Sterile OR Non-Sterile | Non-Sterile |
Use with Non-PHiliphhilip Healthcare Equipment | No |
Product Type | Pads |
Single-Patient Use OR Multi-Patient Use | Single-Patient Use |
Not manufactured with natural rubber latex | Yes |
Minimum Shelf Life | 30 months from date of manufacturing |
Use with Other Supplies | N/A |
Patient Application | Child; Adult |
Conductor Surface Area | 80 cm2 |
Temperature Range for Storage | 0° - 50°C |
Recommended Patient Weight | Any |
Leadwire Length | 1.2 m (3.9') |
Defibrillation Pads
Part NO | 989803166021 | M3713A | M3717A | M3501A | M3504A |
Description | Adult/Child Preconnect Pads | Adult/Child Plus Pads | Infant Plus Pads | Adult/Child Pads with barrel connector | Infant Pads with barrel connector |
Pads per case | 10 | 10 |
5
|
10 | 5 |
Conductor Surface area (cm2 ) |
75
|
75
|
32 | 75 | 32 |
Approx. lead wire length (cm) | 120 | 120 | 60 |
60
|
60 |
No. of hrs on skin | 24 | 24 | 24 | 24 | 24 |
Number of defibrillation shocks | 50 | 50 | 50 | 50 | 50 |
Duration of pacing (hours) at 100mA, 80 bpm | 8 | 8 | 8 | 8 | 8 |
Temperature range for storage | 15˚ – 35˚C | 15˚ – 35˚C | 15˚ – 35˚C | 15˚ – 35˚C | 15˚ – 35˚C |
Shelf life (in months) from date of | 24 | 24 | 24 | 24 | 24 |
Part NO | 989803158211 (1 set) 989803158221 (5 sets) | 989803139261 | 989803149981 (1 set) 989803149991 (5 sets) | M3870A | M5071A | M5072A |
Description | Defibrillator Pads | SMART Pads II | SMART Pads III | FR2 Infant/ Child Pads | Adult SMART Pads Cartridge | Infant/Child SMART Pads Cartridge |
Pads per case | 1 or 5 | 1 | 1 or 5 | 1 | 1 | 1 |
Conductor Surface area (cm2 ) | 85 | 80 | 80 | 85 | 85 | 85 |
Approx. lead wire length (cm) | 120 | 120 | 120 | 120 | 137 | 100 |
No. of hrs on skin | 24 | 24 | 24 | 24 | 24 | 24 |
Number of defibrillation shocks | 50 | 50 | 50 | 50 | 50 | 50 |
Duration of pacing (hours) at 100mA, 80 bpm | 8 | 8 | 8 | N/A | N/A | N/A |
Temperature range for storage | 0˚ – 50˚C | 0˚ – 50˚C | 0˚ – 50˚C | 0˚ – 32˚C | 10˚ – 43˚C | 10˚ – 43˚C |
Shelf life (in months) from date of | 30 | 30 | 30 | 30 | 30 | 30 |
If you're interested in REF 989803149981 PHiliphhilip FR3 AED Heartstart Pads III For Child Adult ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217