Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor

Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor

  • Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor
  • Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor
  • Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor
  • Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor
Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor
Product Details:
Brand Name: Philip
Model Number: M2735A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip Toco+ Transducer Type: M2735A
Application: Medical Equipment,ICU,hospital Device Warranty: 90days
Material: Plastic Product Applications Scenarios: Outpatient Operating Room,Surgical Operating Room,Emergency Operation Room,etc
Preponderance: Original Assembled Real Product Sale Protection: Passion In Serving Our Customer With The Best Service
Languages: Multiple Language Support Product State: Work Well
Rated Voltage Range: 110V—240v Power Supply Source: Electric
Size (diameter): 83 Mm/3.27 In Weight (without Able): < 220 G/7.8 Oz.
Water Ingress Protection Code: IP 68 (immersion Up To 1 M Water Depth For 5 Hours)
High Light:

Philip M2735A Toco Transducer

,

Valon F20 Toco Transducer

 

Philipilip M2735A Toco+ Transducer for Philipilip Avalon F20 FM30 Fetal/Maternal Monitor

 

 

 

► Brief Introduction

Philipilip M2735A Toco+ Transducer can work for Philipilip Avalon F20 FM30 Fetal/Maternal Monitor.

Several parameter frontends are combined on one board. In addition to the Toco frontend, additional supported parameters are DECG, MECG and IUP. A seven-pin ‘D-type’ socket carries all parameter related inputs and outputs. An external mode resistor, connected to one of the pins, automatically detects which mode to set when an adapter cable is plugged in (whether it is DECG, MECG, or IUP).

 

 

Environmental

 

Temperature Range Operating 0°C to 40°C (32°F to 104°F)
Storage -20°C to 60°C (-4°F to 140°F)
Humidity Range Operating <95% relative humidity @ 40°C/104°F
Storage <90% relative humidity @ 60°C/140°F
Altitude Range Operating -500 to 3000 m/-1640 to 9840 ft.
Storage -500 to 13100 m/-1640 to 43000 ft.

 

 

Transducer Cable Assembly

 

Transducer Cable (for all fetal transducers) 1
Sealing Gasket 1
Screw Shoulder M2.5 3
Screw Cover (pack of 3) 1
Transducer Belt Button 1

 

 

► Making Connections

  1. Depending on the equipment you are using, ensure the Toco+ transducer is connected to the fetal monitor.
  2. Connect a pre-gelled foam electrode to each of the two leads on the MECG adapter cable.
  3. Apply the foam electrodes to the patient, following the instructions supplied with the foam electrodes.
  4. Depending on the equipment you are using, connect the pink connector plug on the MECG adapter cable to the pink connector on the Toco+ transducer.

 

Testing the Toco+ Transducer (M2735A): DECG Mode

  1. Switch on the monitor and the recorder.
  2. Connect the patient module or Toco+ transducer to the fetal monitor.
  3. Attach the DECG adapter cable M1362B to the socket on the patient module or Toco+ transducer.
  4. Ensure that the DFHR channel display on the fetal monitor shows the DECG LEADS OFF INOP with the DECG adapter cable attached.
  5. Take a Fetal Scalp Electrode, and connect it to the DECG adapter cable.
  6. EITHER

Make a short between the spiral electrode and the reference electrode with your fingers (it is best to wet your fingers first). Use a sterile Fetal Scalp Electrode.

Philip M2735A Toco Transducer For valon F20 FM30 Fetal / Maternal Monitor 0

OR

Cut off the plastic tip of the fetal scalp electrode (containing the spiral and reference electrodes) from the end of the wires. Strip the insulation from the end of the wires, and connect them to a patient simulator.

 

 

 

 

Thank you for your time! If you are interested in Philipilip M2735A Toco+ Transducer for Philipilip Avalon F20 FM30 Fetal/Maternal Monitor, welcome to place your orders. Early order early shipment! 

If you have any questions, please feel free to contact us at any time, we are glad to answer them.

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217