China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Maxtec |
Model Number: | MAX-250A R125P04-001 |
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | Carton |
Delivery Time: | 3-5 working days |
Payment Terms: | T/T(wire transfer), Western Union, Paypal |
Product Name: | MAX-250A Maxtec Oxygen Sensor R125P04-001 For Spacelabs Blease Sirius 900 | Brand: | Maxtec |
---|---|---|---|
Part No .: | MAX-250A R125P04-001 | Application: | Spacelabs Blease Sirius 900 |
Output: | 10.0 To 15.5 MV In Air At 1013 Millibar Pressure And A Temperature Range Of 23±2 °C | Operating Temperature: | 5° To 40 °C |
Maximum Storage Temperature: | -15° To 50 °C | Optimal Storage Temperature: | 5° To 25 °C |
Range Of Measurement (Full Scale): | 0 To 100% Oxygen | Zero Offset: | Less Than Or Equal To 0.50 MV When Exposed To 99.9% To 100% Nitrogen |
90% Response Time: | Less Than Or Equal To 15 Seconds At 23±2 °C | Linearity: | Within +/- 1.0% Of Full Scale |
Temperature Compensation: | Less Than ± 3.0% From 15° To 40°C | Expected Life: | > 1,500,000% Oxygen Hours Under Normal Operating Conditions |
Humidity: | 5% To 95% Relative Humidity Non-condensing | Recommended Storage Time: | 3 Months |
Highlight: | MAX-250A Maxtec Oxygen Sensor,R125P04-001 Maxtec Oxygen Sensor |
MAX-250A Maxtec Oxygen Sensor R125P04-001 For Spacelabs Blease Sirius 900
The MAX-250 oxygen sensor is a galvanic cell that uses a proprietary weak acid electrolyte which makes the sensor resistant to toxic gases.
Specification
Output | 10.0 to 15.5 mV in air at 1013 millibar pressure and a temperature range of 23±2 °C |
Operating Temperature | 5° to 40 °C |
Maximum Storage Temperature | -15° to 50 °C |
Optimal Storage Temperature | 5° to 25 °C |
Range of Measurement (Full Scale) | 0 to 100% oxygen |
Zero Offset | Less than or equal to 0.50 mV when exposed to 99.9% to 100% nitrogen |
90% Response Time | Less than or equal to 15 seconds at 23±2 °C |
Linearity | Within +/- 1.0% of full scale |
Stability | Less than 1% of full scale over an 8 hour period at constant temperature, pressure, and humidity |
Temperature Compensation | Less than ± 3.0% from 15° to 40°C |
Expected Life | > 1,500,000% oxygen hours under normal operating conditions |
Humidity | 5% to 95% Relative Humidity non-condensing |
Recommended Storage Time | 3 Months |
Sensor life (application dependant) | Approx. 4 years at 20.9 % O2, (Air) * |
Cross Interference |
Less than 0.1% O2 response to: • 0…100% CO2, CO, H2, H2S, CH4, or H2O Bal. N2 • 0…1% NOx Bal N2 |
Pressure Effects |
• Continuous use in pressure range from 0.5…1.5 atm. • Sensor output to be linear with partial pressure of Oxygen within ± 2% of full scale |
The Maxtec oxygen sensor serial number is located on the oxygen sensor label. Lot, job, line item, and serial numbers are all related to the order in which the sensors were manufactured. The model number is listed separately on the label.
How to prolong the Life of an Oxygen Sensor
Maxtec Sensor | Maxtec Part No. | Application |
MAX-250 |
R125P01-002 |
Analytical Industries PSR-11-75-KE1 |
Bemes OXY-1002 | ||
Maxtec OM-25A | ||
Mercury Medical 10-103-11 | ||
Pacifictech PR-250 | ||
Teledyne #C-70592 | ||
MAX--250A | R125P04-001 | Spacelabs Blease Sirius 900 |
MAX-250E |
R125P03-002 |
Analytical Industries PSR-11-917-J1 |
Bemes OXY-3002 | ||
Datascope Anestar S | ||
Fluke Biomedical VT Mobile | ||
Maxtec OM-25ME | ||
Maxtec OM-25AE | ||
Maxtec Max02+AE | ||
Maxtec MaxBlend | ||
Maxtec MaxVenturi | ||
Mercury Medical 10-103-08 | ||
Pacifictech PT-25A | ||
Sensidyne V-25A | ||
Teledyne #C-70592 | ||
Viasys (Bird / Carefusion) Sentry Blender | ||
Viasys (Bird / Carefusion) 66045 Sensor | ||
MAX-250L | R125P13 | Analytical Industries PSR-11-39-JD |
If you have any interest in MAX-250A Maxtec Oxygen Sensor R125P04-001 For Spacelabs Blease Sirius 900 ,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217