Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box

876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box

  • 876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box
  • 876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box
  • 876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box
  • 876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box
876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box
Product Details:
Brand Name: GE
Model Number: 876446-HEL
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: 876446-HEL GE Healthcare D-Fend Water Trap,Black,10pcs/BOX Brand: GE
Ref: 876446-HEL Color: Black
Bacterial Filtration Efficiencies: >99.99998% Viral Filtration Efficiencies: >99.99997%
Tidal Volume Range: The Water Trap Is Located At The End Of The Sidestream Gas Sampling Line. The Sampling Rate Was 200 ML/min. Tidal Volumes Range From 15ml To 2000ml, Depending On The Airway Adapter. Note That Filtration Efficiency Does Not Depend On Tidal Volume. Internal Volume: Container Volume Is > 5.5 ML
Moisture Output Mg/H2o/I At Vt 500ml:: Water Vapor Will Pass Through The Filter, Water Condensate Does Not Resistance: The Maximum Flow Resistance Over The Water Trap Is 20 Mbar At 200mL / Min
Moisture Output (mg H2o/L):: Water Vapor Will Pass Through The Filter, Water Condensate Does Not Packaging Materials: Polyethylene (PE)
High Light:

876446-HEL Patient Monitor Accessories

,

Water Trap Patient Monitor Accessories

876446-HEL GE Healthcare D-Fend Water Trap,Black,10pcs/BOX Multi-Use​

 

 

D-fend water traps help protect respirator from moisture, secretions, viruses and bacteria. The D-fend water collector is suitable for ventilation modules in anesthesia and intensive care environments.

 

The M1182629 D-fend Pro water collector is for multiple patients, while the M1200227 D-fend Pro+ water collector is for single patient use.

Green M1200227, D-fend Pro+ water collector, can be used in an operating room environment, but please note the replacement time according to the instructions for use, which specifies a maximum of 24 hours of use and must be replaced after each patient.

The water collector provides protection for the breathing module.

The PTFE membrane of the D-fend Pro and D-fend Pro+ water traps inhibits the entry of bacteria, viruses, water and mucus into the respiration measurement system.

Filter Type: PTFE oleoPhilipilipobic membrane, 0.2 micron membrane on polyester backing.

D-Fend Pro water traps are designed to protect gas analysis systems from moisture and contaminants and allow for seamless connection

 

characteristic

• Works with GE Healthcare Breathing Module for accurate measurements

• Independent viral filtration efficiency (VFE) testing at an independent third-party lab for an alternative infectious agent called Philipilipi X 174.

 

Product use

 

D-fend water traps are disposable.

 

D-fend+ (881319-HEL)
D-fend Pro+ (M1200227) Critical Care, Maximum 24 hours single-patient-use
D-fend (876446-HEL)
D-fend Pro (M1182629): Anesthesia, Maximum 2 months
Mini D-fend(8002174) Anesthesia, Maximum 2 months. (8002174): Critical Care, Maximum 24 hours, single-patient-use

 

 

Maintenance

 

Do not wash, dry, sanitize or reuse exhausted/clogged water traps. When cleaning the exterior of the module, keep the trap and gas sampling line connected to prevent cleaning agents from entering the trap or gas module

 

Materials

 

  D-fend Pro, D-fend Pro+ D-fend, D-fend+, Mini D-fend
Body Acrylonitrile Butadiene Styrene (ABS) and Polycarbonate (PC) Polyamide (PA)
Top Part Polycarbonate (PC Thermoplastic Elastomer (TPE) N/A
Gasket N/A Silicone rubber
Container Polycarbonate (PC) Thermoplastic Elastomer (TPE) Polycarbonate (PC)
O-Ring N/A Nitrile rubber
Latch Polyoxymethylene (POM) N/A
Filter Polytetrafluoroethylene (PTFE) GORE microfiltration media

 

 

Packaging materials

Primary:Polyethylene (PE)

 

Bacterial and Viral Filtration Efficiency

Part BFE VFE

fend

fend+

Mini D-fend

>99.99998% 99.99997 - 99.99999%
D-fend Pro D-fend Pro+ >99.999970% >99.9988%

876446-HEL Patient Monitor Accessories GE Healthcare D- Fend Water Trap Black 10pcs / Box 0

 

PART LIST

 

Part Number Description QTY
876446-HEL D-fend Water Trap, Black 10
M1182629 D-fend Pro Water Trap, Dark Steel Blue 10
881319-HEL D-fend+ Water Trap, Green 10
M1200227 D-fend Pro+ Water Trap, Green 10
8002174 Mini D-fend Water Trap 10

 

If you're interested in 876446-HEL GE Healthcare D-Fend Water Trap,Black ,10pcs/BOX Multi-Use  ,feel free to contact us.Thank you .

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.