China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | HAMILTON |
Model Number: | C1 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | HAMILTON HEPA Filter | Type: | 161236 00 |
---|---|---|---|
Warranty: | 90days | Applications Scenes: | Ventilator |
Key Word: | HAMILTON-C1 | Product Status: | In Good Working Condition. |
Stock Status: | Stock Available | Minimum Purchasing Quantity: | 1unit |
Temperature Operation:: | 5°C To 40°C (41°F To 104°F) | Temperature Storage:: | -20°C To 60°C (-4°F To 140°F) |
AtmosPHilipheric Pressure: | 620 To 1100 HPa | Relative Humidity: | 10% To 95%, Noncondensing |
Altitude: | -650 To 4000 M (-2,132 To 13,123 Ft) | ||
Highlight: | Particulate Air HEPA Filter,PN 161236 00 HEPA Filter,Mechanical Ventilator HEPA Filter |
HAMILTON medical high efficiency particulate air (HEPA) filter PN 161236 00 for HAMILTON-C1 mechanical Ventilator
► Brief Introduction
This HEPA (High efficiency particulate air) filter is working for HAMILTON-C1 mechanical Ventilator, and PN 161236 00. This is for the fresh air intake and the cooling fan.
HAMILTON-C1 mechanical ventilator requiring only a minimum of space, it combines invasive and noninvasive modes as well as high flow oxygen therapy with maximum mobility. The integrated high-performance turbine enables the HAMILTON-C1 to be completely independent from compressed air. This makes it an ideal companion for all patient groups in the intensive care unit, emergency ward, recovery room or intermediate care as well as in long-term acute care facilities and during intrahospital transport.
► Maintaining the filters
Summarizes the steps to exchange the HEPA filters in the back of the ventilator.
1. Remove and replace air filter.
2. Remove and replace fan filter.
3.Remove back panel.
4. Remove and replace HEPA filter. Replace back cover when finished.
► Preventive maintenance
This perform preventive maintenance on your ventilator
Interval | Part/accessory | Procedure |
Every month (or more often if required) | Fan filters (rear panel), air intake filters (white filters on outside of HEPA filter) | Check for dust and lint. If needed, replace. |
Yearly or as necessary | Air intake HEPA filter | Replace |
► Environmental requirements
Temperature | Operation: | 5°C to 40°C (41°F to 104°F) |
Storage: | -20°C to 60°C (-4°F to 140°F) | |
AtmosPHiliphhiliperic pressure | Operation and storage: | 620 to 1100 hPa |
Relative humidity | Operation and storage: | 10% to 95%, noncondensing |
Altitude | -650 to 4000 m (-2,132 to 13,123 ft) Note that at higher altitudes the ventilator performance may be limited. The Performance limited by high altitude alarm is generated and a message is shown on the display |
► About Company
We have supply the Parts, Accessories and medical equipment of Patient Monitor, Defibrillator Machine, ECG Machine, Ventilator, Anesthesia Machine, Ultrasound such as
GE,
PHiliphhilip,
Mindray,
Goldway,
Nihon Kohden,
Med-tronic,
Masima,
Drager,
Edan,
Zoll,
etc.
Please kindly contact us, if you are interested in HAMILTON medical high efficiency particulate air (HEPA) filter PN 161236 00 for HAMILTON-C1 C1 mechanical Ventilator, Thank you!
Contact Person: Bella
Tel: 86-18879075074