Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsDefibrillator Machine Parts

REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery

REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery

  • REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery
  • REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery
  • REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery
  • REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery
Product Details:
Brand Name: Med-tronic
Model Number: 21330-001176
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: REF21330-001176 Med-tronic PhilipYSIO-CONTROL LIFEPAK 15 LP 15 LITHIUM-ION Rechargeable Battery Brand: Med-tronic
Part No .: 21330-001176 Battery Type: Lithium-ion
Weight: 0.59 Kg (1.3 Lb) Voltage: 11.1V Typical
Capacity (rated): 5.7 Amp Hours Charge Time (with Fully Depleted Battery): 4 Hours And 15 Minutes (typical)
Battery Indicators: Each Battery Has A Fuel Gauge That Indicates Its Approximate Charge. A Fuel Gauge That Shows Two Or Fewer LEDs After A Charge Cycle Indicates That The Battery Should Be Replaced. Charging Temperature Range: 0° To 50°C (32° To 122°F)
Operating Temperature Range: 0° To 50°C (32° To 122°F) Short Term (<1 Week) Storage Temperature Range: -20° To 60°C (-4° To 140°F)
Long Term (>1 Week) Storage Temperature Range: 20° To 25°C (68° To 77°F) Operating And Storage Humidity Range: 5 To 95% Relative Humidity, Non-condensing
High Light:

REF21330-001176 Defibrillator Machine Parts

,

Lithium Ion Battery Defibrillator Machine Parts

,

Defibrillator Lithium Ion Rechargeable Battery

REF21330-001176 Med-tronic PhilipilipYSIO-CONTROL LIFEPAK 15 LP 15 LITHIUM-ION Rechargeable Battery
 
 
Med-tronic lifepak 15 device is powered by two LIFEPAK 15 rechargeable lithium-ion (Li-Ion) batteries. The battery communicates through contacts on the bottom of the battery. This allows you to exchange of information about battery type, amp hours rating, charge rate, target voltage, current, and other parameters
 
 
Battery Specifications
 

CHARACTERISTIC DESCRIPTION
Battery Type Lithium-ion
Weight 0.59 kg (1.3 lb)
Voltage 11.1V typical
Capacity (rated) 5.7 amp hours
Charge Time (with fully depleted battery) 4 hours and 15 minutes (typical)

 
 
Battery indicators

Each battery has a fuel gauge that indicates its approximate charge. A fuel gauge that shows two or fewer LEDs after a charge cycle indicates that the battery should be replaced.
Charging Temperature Range 0° to 50°C (32° to 122°F)
Operating Temperature Range 0° to 50°C (32° to 122°F)
Short Term(<1 week) Storage Temperature Range -20° to 60°C (-4° to 140°F)
Long Term (>1 week) Storage Temperature Range 20° to 25°C (68° to 77°F)
Operating and Storage Humidity Range 5 to 95% relative humidity, non-condensing

 
 
 
 
The LIFEPAK 15 lithium-ion battery, charger and power cord cannot be replaced by the batteries, charger and power cord used in other LIFEPAK defibrillators.
 
 
The home screen shows a battery indicator that shows the following information about the battery installed in the device:
• With or without batteries in the battery compartment.
• The battery is in use.
• Battery charging mode.
When installing two batteries The device will use the battery with the lowest charge level first. Used batteries are indicated by the white battery number in the black box. when the battery reaches the mode "Replace battery", the device will automatically switch to a different battery.
 
 

Indicator Meaning Description
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 0 Active battery The device is running on battery in Well 1. The battery status indicator shows up to four green bars. Each green bar represents approximately 25% remaining charge. For example, three green bars indicate about 75% remaining charge.
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 1 Low battery The battery in Well 1 is in use and low. A yellow bar indicates 5% to 10% charge remaining.
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 2 Very low battery The battery in Well 1 is in use and is very low. A flashing red bar indicates 0% to 5% battery remaining. The device will automatically switch to another battery only when the battery is fully charged. If both batteries show red bars, the battery replacement voice prompt appears.
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 3 Unrecognized battery The battery in well 2 is not used. Battery communication failed or non-PhilipilipysioControl battery installed. The battery can power the device, but the charge level is unknown and no low battery messages or warnings are displayed
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 4 No battery installed or fault detected No batteries are installed in well 1, or a battery error has been detected in well 1 and the tool is not using batteries.

 
 
Battery Fuel Gauge
 
The LIFEPAK 15 Li-Ion battery has a push-button fuel gauge and is able to communicate with the Li-Ion battery charger.
The push-button fuel gauge provides a visual indication of battery capacity and battery condition through a series of four green LEDs. Press this button to light the LED in one of the following modes:
 
 

# Fuel Gauge LEDs Absolute State of Charge (ASOC) Messaging/Comments
4 green 75% < ASOC None
3 green 50% < ASOC None
2 green 25% < ASOC None
1 green 15% < ASOC None
1 yellow 5% < ASOC LOW BATTERY
1 flashing red ASOC £ 5% REPLACE BATTERY

 
REF21330-001176 Defibrillator Machine Parts Med-tronic Philipysio Control Lifepak 15 LP 15 Lithium Ion Rechargeable Battery 5
 
Battery Operation Only
 
Maximum Time from Charge to Shock Ready (Manual Mode)

Battery Status Charge Time
Fully charged 200 J within 7 seconds, nominal
Fully charged, followed by 15 full-energy shocks 360 J within 10 seconds
Fully charged 360 J within 10 seconds

 
Maximum Time from Initiation of Analysis to Shock Ready (AED Mode):
 

Battery Status Charge Time
Fully charged 200 J within 15 seconds, nominal
Fully charged, followed by 15 full-energy shocks 360 J within 30 seconds
Fully charged 360 J within 30 seconds

 
 
Maximum Time from Power-on to Shock Ready (Manual Mode):
 

Battery Status Charge Time
Fully charged, followed by 15 full-energy shocks 360 J within 25 seconds

 
 
Maximum Time from Power-on to Shock Ready (AED Mode):
 

Battery Status Charge Time
Fully charged, followed by 15 full-energy shocks 360 J within 40 seconds

 
 
If you’re interested in REF21330-001176 Med-tronic PhilipilipYSIO-CONTROL LIFEPAK 15 LP 15 LITHIUM-ION Rechargeable Battery ,feel free to contact us .Thank you .
 
 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.