Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C 801-6101-00016-00

Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C 801-6101-00016-00

  • Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00
  • Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00
  • Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00
  • Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00
Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00
Product Details:
Brand Name: Mindray
Model Number: Passport V
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Mindray Spo2 Board Type: Passport V
PN: MS-2013 31888 Rev C 801-6101-00016-00 Warranty: 90days
Product Superiority: Original Product Conditions: In Good Working Condition
Waveforms:: 3 To 8. SpO2 Measurement Range: From 1% To 100%
Resolution: 1% Average Time: Optional 2-4 Seconds, 4-6 Seconds, 8 Seconds, 10 Seconds, 12 Seconds, 14 Seconds, 16seconds
Refresh Rate: 1s Transport And Storage Humidity: 5 To 95%, Non-condensing
Multi-language Supported Interface: English, French, German, Italian, Spanish, Brazilian-Portuguese, Russian,Dutch
High Light:

Mindray Passport V Patient Monitor Parts

,

Spo2 Board Patient Monitor Parts

,

MS-2013 31888 Spo2 Board

 

Mindray passport V patient monitor spo2 board MS-2013 31888 Rev C 801-6101-00016-00

 

 

 

► Brief Introduction

This is Masi-mo-2013 SpO2 module.

An isolation power board is attached to each of them and used to isolate the DC power and the UART signal of the OEM SpO2 modules from other circuits in the main unit. The UART signal comes from the CPU board and passes through the power management and interface board.

 

 

Masi-mo SpO2 PCB Assembly

Passport V Patient Monitor Parts Spo2 Board MS-2013 31888 Rev C  801-6101-00016-00 0

1 Large Flat Washer, GB96 3
2 Spring Washer, GB93 3
3 Screw, Stud M3X7
4 PCBA, Masi-mo Transfer Board
5 Communication cable. OEM SpO2
6 Screw, Pan Head W/Washer Philipilipillips M3X6
7 Nut, Stainless Steel M3 GB6170
8 Washer, insulating 3X1mm
9 SpO2 flex cable assembly 2685
10 Screw, Flat Head PhilipilipillipsM2.5X4
11 Frame, Masi-mo SpO2 Connector
12 Screw, Self-Tapping PT3X8
13 Screw, Pan Head Philipilipillips M3X6
14 Masi-mo MS-2013 board

 

 

Removal of the Masi-mo SpO2 Module

1. Remove the multi-parameter board assembly.

2. Disconnect the SpO2 communication cable from the multi-parameter board.

3. Cut the tie of flexible cable.

4. Unfasten the screw that secures the Masi-mo SpO2 module to the multi-parameter board installation frame.

5. Unfasten the two screws that secure the Masi-mo SpO2 connector.

6. Remove the Masi-mo SpO2 module.

 

 

 

SpO2 Verification
1. Connect the patient simulator to the SpO2 connector on the monitor.
2. Select the model and the manufacturer of the SpO2 module under test, and then configure the patient simulator as follows: SpO2 96%; PR 80 bpm.
3. The displayed SpO2 and PR values should be within the following ranges: DPM, Masi-mo, and Nellcor SpO2: 96% ± 2% PR (bpm):80 ± 3
4. Verify that SpO2 displays the pleth waveform, and the SpO2 indicates a valid reading. Verify the HR source is SpO2 and a beep tone is present.
CAUTION: A functional tester cannot be used to assess the accuracy of the pulse oximeter probe or a pulse oximeter monitor.

 

 

SpO2 Troubleshooting

MESSAGE/ PROBLEM REASON SOLUTION
SpO2: Interference Noise detected on the pulse signal prevents pulse discrimination. Decrease patient motion,check sensor.
SpO2: Low Perfusion Patient perfusion is low Check to patient connection and patient status.
SpO2: Too Much Light There is too much ambient room light for the sensor to function properly. Minimize the room light around the patient. Check sensor.

 

 

 

 

Thank you for your time and interest in Mindray passport V patient monitor spo2 board MS-2013 31888 Rev C 801-6101-00016-00

Any inquiry will be highly appreciated and thanks for your support. 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2023 patients-monitor.com. All Rights Reserved.