Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Accessories

6850645 Patient Monitor Accessories Ventilator Oxygen Sensor

6850645 Patient Monitor Accessories Ventilator Oxygen Sensor

  • 6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
  • 6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
  • 6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
  • 6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
  • 6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
6850645 Patient Monitor Accessories Ventilator Oxygen Sensor
Product Details:
Brand Name: Dräger
Model Number: 6850645
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: Part No 6850645 Dräger Evita 4 Ventilator Oxygen Sensor Brand: Drager
Part No .: 6850645 Measuring Range: 0 To 100 % By Vol. Oxygen
Response Time T10-90: 16 Sec Operating Temperature: 15 To 40 °C
Storage Temperature: -20 To 40 °C Dimensions: Ø 28 Mm, Height 22 Mm
Warranty: 90 Days MOQ: One Piece
Condition: New And Original
High Light:

6850645 Patient Monitor Accessories

,

Ventilator Oxygen Sensor Patient Monitor Accessories

,

Height 22mm Ventilator Oxygen Sensor

Part No 6850645 DräGer Evita 4 Ventilator Oxygen Sensor Original New

 

Part No 6850645 Dräger Evita 4 Ventilator Oxygen Sensor

 

 

About O2 sensor 68 50 645

 

Introduced in 1977, the O2 sensor capsule is used to measure and monitor inhaled O2 concentrations in anesthesia and intensive care equipment. Since then, more than 1.6 million* sensors have been manufactured and shipped worldwide. This sensor is used in devices such as Fabius series, Evita series, Incubator 8000, Cicero A/B and Oxydig. O2 sensor capsules have a lifespan of more than 12 months

 

 

Fast O2 sensors 68 50 930

 

Fast O2 sensors were introduced to the market in 1994 as a method of measuring and monitoring inspiratory and expiratory O2 concentrations with respiratory resolution. Since then, more than 470,000 sensors have been shipped worldwide. This sensor is used in devices such as Primus, Julian, Cicero EM, Cato, PM8060, PM8050, etc. The fast O2 sensor has a lifespan of more than 6 months.

 

 

The Dräger O2 sensor is an electrochemical system for measuring the partial pressure of O2. The sensor works on the principle of galvanic cells. The gas mixture to be monitored diffuses through the plastic membrane into the sensor electrolyte. The electrolyte consists of a working electrode (gold electrode) and a counter electrode (lead electrode). The oxygen to be monitored is electrochemically reduced at the working electrode.

O2 + 2H2O + 4e- → 4OH: while the counter electrode is oxidized:

2Pb → 2Pb2 + + 4eA generates a current that is proportional to the partial pressure of O2 in the mixed gas to be monitored.

 

Benefits

 

- 100% system compatibility with Dräger devices and systems

- High measurement accuracy with above-average quality standards and extensive testing

-Compliance with national and international requirements

 

 

 

 

O2 sensor capsule

(68 50 645)

Fast O2 sensor

(68 50 930)

Measuring range: 0 to 100 % by vol. oxygen 0 to 100 % by vol. oxygen
Response time T10-90 16 sec 0.5 sec.
Operating temperature: 15 to 40 °C 15 to 40 °C
Storage temperature: -20 to 40 °C -20 to 40 °C
Dimensions Ø 28 mm, height 22 mm Ø 11 mm, height 13 mm

 

 

 

Calibrating

The last calibration/zero value is stored until the next calibration/zero, even if the machine is turned off. The pressure sensor used to measure airway pressure is calibrated automatically. The flow and O2 sensors are calibrated automatically every day.

The flow sensor can be calibrated manually at any time, even during ventilation

The O2 sensor can be calibrated manually at any time, even during ventilation. The applied O2 concentration is not affected by calibration. CO2 sensor calibration can be checked during ventilation

 

O2 . sensor calibration

- Before operation, during equipment inspection.

- After replacing the O2 sensor (allow 15 minutes for the O2 heating time if the deviation between the measured value and the set value exceeds 2% by volume).

The O2 sensor can be calibrated during ventilation.

Start calibration: Press the button »Calibrate«. Screen (example):

Press the key »O2«.

»LED« display button changes color to yellow.

Message in the instructions at the bottom of the screen: O2 calibration After calibration is complete, the yellow »LED« on the display button goes out.

 

6850645 Patient Monitor Accessories Ventilator Oxygen Sensor 0

 

6850645 Patient Monitor Accessories Ventilator Oxygen Sensor 1

 

 

 

 

 

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.