P/N 9005-30-08530 Patient Monitor Parts Mindray PM7000 PM8000 PM9000 Spo2 Board

P/N 9005-30-08530 Patient Monitor Parts Mindray PM7000 PM8000 PM9000 Spo2 Board

  • P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board
  • P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board
  • P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board
  • P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board
P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board
Product Details:
Brand Name: Mindray
Model Number: 9005-30-08530
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: P/N 9005-30-08530 Mindray PM7000 PM8000 PM9000 Patient Monitor Spo2 Board Brand: Mindray
Part No: 9005-30-08530 MOQ: One Piece
Warranty: 90 Days Condition: Used
Compatible Equipment: PM7000 ,PM8000 ,PM9000 Payment Terms: Full Before Shipment
Delivery Time: 3-5 Working Days Delivery Method: DHL,UPS ,Fedex ,etc
High Light:

9005-30-08530 Patient Monitor Parts

,

Mindray PM7000 Patient Monitor Parts

,

Patient Monitor Spo2 Board

P/N 9005-30-08530 Mindray PM7000 PM8000 PM9000 Patient Monitor Spo2 Board

 

 

The monitor measures the patient's SpO2 (oxygen saturation) and displays the following information:

1.Pulse value (PR) in the ECG parameter window.

2. Waveform of PLETH in waveform section.

3. The oxygen saturation value (SpO2%) in the SpO2 parameter window.

 

 

The PR value is only displayed in the ECG parameter window if:

1. SpO2 is selected in the HR DA setting in the ECG SETUP menu.

2. If AUTO is selected in the HR DA setting in the ECG SETUP menu, no ECG signal is received.

 

As shown in the figure below, the PLETH waveform is on the left and the SpO2 parameter window is on the right. The SpO2 value is given as a percentage, followed by the perfusion rate (proportional to the pulse intensity). You can also access the SpO2 Settings menu from the SpO2 tab in the upper left corner of the parameter window.

 

P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board 0

1. PLETH waveform 2. SPO2 label 3. SpO2 value 4. Perfusion indicator

 

 

SpO2 monitoring is a noninvasive technique for measuring the amount and pulse rate of oxyhemoglobin by measuring the absorbance of selected wavelengths of light.

 

The light produced by the researcher travels through the network and is converted into an electrical signal with a Philipilipotodetector in the researcher's house. The SpO2 module processes the electrical signal and displays the digital SpO2 and waveform and pulse values on the screen.

The measuring wavelength of the sensor is nominally 660 nm for red LEDs and 940 nm for infrared LEDs. The maximum LED output power is 4 mW.

 

Item name

Mindray PM7000 PM8000 PM9000 patient monitor spo2 board

 

Brand Mindray
Model 9005-30-08530
Use place Hospital Devices; Medical Care; ICU;
Deliver time 3-5 days
Warranty 90 days

 

Spo2 Monitoring Procedure

 

The choice of sensor for SpO2 measurement depends on the type of patient. Finger SpO2 sensor is selectable for adult patients. For newborns, you can choose a hand or foot sensor. See the steps below.

1. Turn on the screen.

2. Attach the sensor to the appropriate location on the patient.

3. Connect the sensor extension cable connector to the SpO2 connector on the monitor.

P/N 9005-30-08530 Patient Monitor Parts  Mindray PM7000 PM8000 PM9000 Spo2 Board 1

 

Spo2 Measurement Limitations

 

If the accuracy of any measurement seems unreasonable, first check the patient's vital signs by an alternative method. Then check if the instrument is working properly. Inaccurate measurements can be caused by:

Faulty SpO2 sensor;

  • high-frequency electrical noise, including noise generated by the host system, or noise from external sources, such as electrosurgery equipment connected to the system;
  • Oximeter and SpO2 Sensors Used During Magnetic Resonance Imaging (MRI)
  • scan. The induced current can cause burns;
  • Intravascular dye injection;
  • Excessive patient movement;
  • Excessive ambient light;
  • Incorrect sensor installation or wrong sensor placement on the patient
  • Sensor temperature (optimal temperature between 28°C and 42°C);
  • Sensors placed on limbs connected to blood pressure cuffs, arterial catheters, or intravascular lines;
  • Dysfunctional hemoglobin concentrations, such as carboxyhemoglobin and methemoglobin;
  • SpO2 is too low;
  • Low circulatory perfusion in the applied part;
  • Shock, anemia, hypothermia, and vasomotor application all reduce arterial blood flow and may affect pulse oximetry.

 

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Andy

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2023 patients-monitor.com. All Rights Reserved.