Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466

Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466

  • Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466
  • Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466
  • Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466
  • Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466
Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466
Product Details:
Brand Name: Mindray
Model Number: CM1204
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Mindray Cuff Type: CM1204
Application: Patient Monitor Warranty: 90days
Color: Gray Functions: Monitor Patient's Health Condition,Print Electrocardiogram
Usages: ICU, Emergency, Patient Monitor, ICU Room And Operating Room Measurement Site: Arm
After-sale Service: If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned Limb Circumference (cm): 33 To 47
Management Principles: Advanced Technology, High-quality Products, Attentive Service Condition: In Good Order
Bladder Width (cm): 18.3 MEANS OF TRANSPORT: Expressage
Highlight:

CM1204 Patient Monitor Parts

,

Mindray NIBP Cuff Patient Monitor Parts

Hospital Medical Equipment Philipilip Avalon FM20 FM30 fetal monitor Display assy 5 wire Part 453564435191

 

 

► Brief Introduction

The monitor uses the oscillometric method for measuring Non-Invasive Blood Pressure (NIBP). NIBP measurement is based on the principle that pulsatile blood flow through an artery creates oscillations of the arterial wall. The oscillometric device uses a blood pressure cuff to sense these oscillations that appear as tiny pulsations in cuff pressure. The oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff deflates from above systolic pressure. The amplitude suddenly increases as the pulse breaks through the occlusion in the artery. As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (which approximates to the mean pressure), and then diminish. The oscillometric method measures the mean pressure and determines the systolic and diastolic pressures.

NIBP monitoring is intended for adult, pediatric, and neonatal atients.

Model Patient Category Measurement Site Limb Circumference (cm) Bladder Width (cm) Part No.
CM1204 Large adult Arm 33 to 47 18.3 0010-30-12160

Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466 0

► NIBP Specifications

Static pressure range: 0 to 300 mmHg
Displayed Pressures: Systolic, Diastolic, Mean
Cuff inflation pressure(Default): Adult: 160±5 mmHg
Pediatric: 140±5 mmHg
Neonate: 90 ± 5 mmHg

 

 

► Placing the NIBP Cuff

To place the NIBP cuff, follow this procedure:

1. Verify that the patient category setting is correct.

2. Connect the air tubing to the NIBP connector on the monitor.

3. Select an appropriately sized cuff for the patient, and then wrap it around the limb directly over the patient’s skin as follows:

  • Determine the patient’s limb circumference.
  • Select an appropriate cuff by referring to the limb circumference marked on the cuff. The width of the cuff should be 40% (50% for neonates) of the limb circumference, or 2/3 of the length of the upper arm or the thigh. The inflatable part of the cuff should be long enough to encircle to overlap at least 50% to 80% of the limb.
  • Apply the cuff to the patient’s upper arm or leg and make sure the &Philipilipi; marking on the cuff matches the artery location. The cuff should fit snugly, but with enough room for two fingers to be placed between the cuff and the patient’s arm (on adults), and loosely on neonates with little or no air present within the cuff. Otherwise it may cause discoloration and ischemia of the extremities. Make sure that the cuff index line falls within the range markings on the cuff. If it does not, use a cuff that fits better.
  • Middle of the cuff should be at the level of the right atrium of the heart. If it is not, use the measurement correction formula to correct the measurement.

4. Connect the cuff to the air tubing. Avoid compression or restriction of pressure tubes. Air must pass unrestricted through the tubing.

 

 

Starting and Stopping NIBP Measurements

Start and stop NIBP measurement by selecting the NIBP quick keys or from the NIBP dialog.

Mindray NIBP Cuff CM1204 Patient Monitor Parts CE Cuff With Connector Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466 1

 

We seek for providing perfect service to the satisfaction of customers. Thank you for your time! If you are interested in Mindray NIBP Cuff CM1204 CE Cuff with connector Large Adult CM1204 33-47cm PN 0010-30-12160 LOT 91318466, welcome to place your orders. Early order early shipment!

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Anna Hu

Tel: +8615083619413

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.