Brand Name: | Mindray |
Model Number: | CM1204 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Mindray Cuff | Type: | CM1204 |
---|---|---|---|
Application: | Patient Monitor | Warranty: | 90days |
Color: | Gray | Functions: | Monitor Patient's Health Condition,Print Electrocardiogram |
Usages: | ICU, Emergency, Patient Monitor, ICU Room And Operating Room | Measurement Site: | Arm |
After-sale Service: | If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned | Limb Circumference (cm): | 33 To 47 |
Management Principles: | Advanced Technology, High-quality Products, Attentive Service | Condition: | In Good Order |
Bladder Width (cm): | 18.3 | MEANS OF TRANSPORT: | Expressage |
Highlight: | CM1204 Patient Monitor Parts,Mindray NIBP Cuff Patient Monitor Parts |
Hospital Medical Equipment Philipilip Avalon FM20 FM30 fetal monitor Display assy 5 wire Part 453564435191
► Brief Introduction
The monitor uses the oscillometric method for measuring Non-Invasive Blood Pressure (NIBP). NIBP measurement is based on the principle that pulsatile blood flow through an artery creates oscillations of the arterial wall. The oscillometric device uses a blood pressure cuff to sense these oscillations that appear as tiny pulsations in cuff pressure. The oscillometric devices measure the amplitude of pressure changes in the occluding cuff as the cuff deflates from above systolic pressure. The amplitude suddenly increases as the pulse breaks through the occlusion in the artery. As the cuff pressure decreases further, the pulsations increase in amplitude, reach a maximum (which approximates to the mean pressure), and then diminish. The oscillometric method measures the mean pressure and determines the systolic and diastolic pressures.
NIBP monitoring is intended for adult, pediatric, and neonatal atients.
Model | Patient Category | Measurement Site | Limb Circumference (cm) | Bladder Width (cm) | Part No. |
CM1204 | Large adult | Arm | 33 to 47 | 18.3 | 0010-30-12160 |
► NIBP Specifications
Static pressure range: | 0 to 300 mmHg |
Displayed Pressures: | Systolic, Diastolic, Mean |
Cuff inflation pressure(Default): | Adult: 160±5 mmHg |
Pediatric: 140±5 mmHg | |
Neonate: 90 ± 5 mmHg |
► Placing the NIBP Cuff
To place the NIBP cuff, follow this procedure:
1. Verify that the patient category setting is correct.
2. Connect the air tubing to the NIBP connector on the monitor.
3. Select an appropriately sized cuff for the patient, and then wrap it around the limb directly over the patient’s skin as follows:
4. Connect the cuff to the air tubing. Avoid compression or restriction of pressure tubes. Air must pass unrestricted through the tubing.
► Starting and Stopping NIBP Measurements
Start and stop NIBP measurement by selecting the NIBP quick keys or from the NIBP dialog.