China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | PHiliph |
Model Number: | CM10 CM12 CM15 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Parameter Board | Type: | CM10 CM12 CM15 |
---|---|---|---|
Application: | Patient Monitor | Warranty: | 90days |
Color: | Green | Dominant Position: | Original,Specialized Engineers With 12 Years Of Experience |
Condition: | In Good Form | Inventory Situation: | Stock Available |
Index Terms: | Accessories,Consumable Items | Applications Scenario: | Hospital; Clinic; Hospital Room; ICU;Inpatient Ward |
Operating Temperature:: | 10° To 40° C | Storage Temperature:: | ‑20° To 50° C |
Operating/storage Relative Humidity:: | 15 – 90% RH, Non‑condensing | AtmosPHilipheric Pressure:: | 1013 – 701 Mbar, 0 – 3000 Meters, 0 – 9842 Feet Above Sea Levell |
Alarm Audio Range: | 45 – 85 DB, ± 3 DB Tolerance | Frequency:: | 50/60 Hz |
Highlight: | CM15 Patient Monitor Parameter Board,CM10 Patient Monitor Parameter Board |
Hospital Bedside Monitor Machine PHiliphhilip Efficia CM10 CM12 CM15 patient monitor parameter board
►Brief Introduction
PHiliphhilip Efficia CM patient monitors help you monitor, analyze, record and alert multiple PHiliphhilipysiological parameters, bedside, to adult, child and newborn patients. Screens can also help you in transportation parking spaces within your facility.
Efficia's patient monitor provides you with information on the electrocardiogram, primary arrhythmia, ST and SpO2 analysis (PHiliphhilip FAST SpO2, Masima rainbow SET* or Nellcorrr OxiMax), non-invasive blood pressure, dual temperature and breathing resistance. Screens can also help you measure:
► Features
► Measurement specifications
ECG
1 | Heart rate range: | Adult: 15 – 300 bpm Pediatric and neonatal: 15 – 350 bpm |
2 | Heart rate accuracy: | ± 1% or ± 1 bpm, whichever is greater |
3 | Bandwidth: | Normal monitoring: 0.67 – 40 Hz Filtered monitoring: 0.6 – 20 Hz Extended monitoring: 0.05 – 100 Hz |
4 | Pacemaker detection: | indicator of pace pulse on waveform display (user-selectable) |
5 | ECG size (sensitivity): | 4,0, 2.0, 1.0, 0.5, 0.25 cm/mV or Auto |
SpO2
• Measurement range
- SpO2: 0 – 100%
- SpO2 resolution: 1%
- Pulse rate: 30 – 300 bpm
- Pulse rate resolution: 1 bpm
• Pulse rate accuracy: 2% or 1 bpm, whichever is greater
• SpO2 accuracy* (within the range 70 – 100%),
• Wavelength range**: 500 – 1000 nm for all specified sensors
• Maximum optical output power: ≤ 15 mW for all specified sensors
Invasive blood pressure
• Measurement range: -40 to 360 mmHg
• Input sensitivity: 5 µV/V/mmHg
• Zero static offsets: up to ± 200 mmHg with ± 1 mmHg accuracy
• Gain accuracy
- Accuracy: ± 1%
- Drift: less than 0.05%/° C • Overall accuracy (including transducer): ± 4 mmHg or ± 4%, whichever is greater
• Volume displacement of CPJ840J6: 0.2 mm3/100 mmHg
• Warm up time of equipment and transducer: < 15 seconds
Noninvasive blood pressure (NBP)
• Technique: oscillometric, using stepwise deflation pressure
• Adult measurement range
- Systolic: 30 – 270 mmHg (4.0 – 36.0 kPa)
- Diastolic: 10 – 245 mmHg (1.3 – 32.7 kPa)
- MAP: 20 – 255 mmHg (2.7 – 34.0 kPa)
• Pediatric measurement range
- Systolic: 30 – 180 mmHg (4.0 – 24.0 kPa)
- Diastolic: 10 – 150 mmHg (1.3 – 20.0 kPa)
- MAP: 20 – 160 mmHg (2.7 – 21.3 kPa)
• Neonatal measurement range
- Systolic: 30 – 130 mmHg (4.0 – 17.3 kPa)
- Diastolic: 10 – 100 mmHg (1.3 – 13.3 kPa)
- MAP: 20 – 120 mmHg (2.7 – 16.0 kPa
• Blood pressure accuracy
- Maximum standard deviation: ≤ 8 mmHg
- Maximum mean error: ± 5 mmHg
• Pulse rate range: 40 – 300 bpm
• Pulse rate accuracy (average over the NBP cycle)
- 40 – 100 bpm: ± 5 bpm
- 101 – 200 bpm: ± 5% of reading
- 201 – 300 bpm: ± 10% of reading
• Initial cuff inflation
- Adult: 160 mmHg (21.3 kPa)
- Pediatric: 140 mmHg (18.7 kPa)
- Neonatal: 100 mmHg (13.3 kPa)
• NBP intervals: automatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes and STAT
Temperature measurements
• Measurement range for all measurement sites: 0° to 50° C (32° to 122° F)
• Accuracy ± 0.1° C – without temperature probe
• Mode of operation: direct mode
• Heating and cooling transient response time: ≤ 150 s
Microstream CO2
• Measurement range: 0 – 150 mmHg
• Data sample rate: waveform sampling, 20 samples per second
• Flow rate: 50 ml/min, + 15 ml/min, –7.5 ml/min
• CO2 waveform resolution: 0.1 mmHg
• etCO2, imCO2 resolution: 1.0 mmHg
• Initialization and power-up time: 40 seconds (typical), 3 minutes maximum
• Total response time for adults/pediatrics is approximately 3.9 seconds, for 10% – 90% changes in CO2 concentration
• The maximum CO2 response time (with a standard-length FilterLine) is 5.3 seconds (typical).
• Calibration interval: initial calibration after one year or 1,200 hours, whichever comes first; then once per year, or every 4000 hours, whichever comes first
• Auto zero interval: once per hour (typical)
• Leak tightness: < 250 mBar/min when a 30% vacuum is invoked on the flow system
• Accuracy (for respiratory rates up to 80 rpm):
- ± 2 mmHg in the range 0 mmHg – 38 mmHg
- ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg in the range 39 mmHg – 150 mmHg
• Respiration rate range: 0 – 150 rpm
• Respiration accuracy
- ± 1 rpm in the range 0 – 70 rpm
- ± 2 rpm in the range 71 – 120 rpm
- ± 3 rpm in the range 121 – 150 rpm
• Automatic barometric pressure: automatic pressure compensation
• Effects of cyclical pressure
- Overpressure: + 100 cmH2O
- Underpressure: –20 cmH2O
Thank you for your time! If you want to explore more details about PHiliphhilip Efficia CM10 CM12 CM15 patient monitor parameter board, please let us know. Customer satisfaction. Our biggest pursuit!