Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board

PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board

  • PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board
  • PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board
  • PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board
  • PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board
PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board
Product Details:
Brand Name: PHiliph
Model Number: CM10 CM12 CM15
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Parameter Board Type: CM10 CM12 CM15
Application: Patient Monitor Warranty: 90days
Color: Green Dominant Position: Original,Specialized Engineers With 12 Years Of Experience
Condition: In Good Form Inventory Situation: Stock Available
Index Terms: Accessories,Consumable Items Applications Scenario: Hospital; Clinic; Hospital Room; ICU;Inpatient Ward
Operating Temperature:: 10° To 40° C Storage Temperature:: ‑20° To 50° C
Operating/storage Relative Humidity:: 15 – 90% RH, Non‑condensing AtmosPHilipheric Pressure:: 1013 – 701 Mbar, 0 – 3000 Meters, 0 – 9842 Feet Above Sea Levell
Alarm Audio Range: 45 – 85 DB, ± 3 DB Tolerance Frequency:: 50/60 Hz
Highlight:

CM15 Patient Monitor Parameter Board

,

CM10 Patient Monitor Parameter Board

 

 Hospital Bedside Monitor Machine PHiliphhilip Efficia CM10 CM12 CM15 patient monitor parameter board

 

 

 

►Brief Introduction

PHiliphhilip Efficia CM patient monitors help you monitor, analyze, record and alert multiple PHiliphhilipysiological parameters, bedside, to adult, child and newborn patients. Screens can also help you in transportation parking spaces within your facility.

Efficia's patient monitor provides you with information on the electrocardiogram, primary arrhythmia, ST and SpO2 analysis (PHiliphhilip FAST SpO2, Masima rainbow SET* or Nellcorrr OxiMax), non-invasive blood pressure, dual temperature and breathing resistance. Screens can also help you measure:

  • Double-penetrating blood pressure
  • Sidestream CO2 (Respironics LoFlo, Respironics CapnoTrak and Microstream) or Mainstream (Respironics Capnostat)
  • Improved arrhythmia analysis

 

► Features

  • Easy selection of diff erent display layouts
  • Retrospective clinical information review from up to 240 hours of tabular and graPHiliphhilipical trends and optional 48 hours full disclosure
  • Lithium‑ion battery, with practical access slots – making it simple to change the battery (with a standard, fl at‑head screwdriver)
  • Audible and visual alarm indicators
  • Compatible with a wide range of PHiliphhilip supplies and accessories
  • Connectivity to Effi cia rack and modules
  • Connectivity to central station
  • Interface to other systems using HL7 data over the serial connection, or LAN/optional WLAN
  • Password‑protected administrator and maintenance
  • Easy software upgrades over the USB port
  • Automatic or prompted patient ID entry using the optional barcode scanner support
  • Optional integrated recorder for easy printing of patient data
  • Optional roll stand, or wall mounts

 

► Measurement specifications

ECG

1 Heart rate range: Adult: 15 – 300 bpm
Pediatric and neonatal: 15 – 350 bpm
2 Heart rate accuracy: ± 1% or ± 1 bpm, whichever is greater
3 Bandwidth: Normal monitoring: 0.67 – 40 Hz
Filtered monitoring: 0.6 – 20 Hz
Extended monitoring: 0.05 – 100 Hz
4 Pacemaker detection: indicator of pace pulse on waveform display (user-selectable)
5 ECG size (sensitivity): 4,0, 2.0, 1.0, 0.5, 0.25 cm/mV or Auto

 

SpO2

• Measurement range

  - SpO2: 0 – 100%

  - SpO2 resolution: 1%

  - Pulse rate: 30 – 300 bpm

  - Pulse rate resolution: 1 bpm

• Pulse rate accuracy: 2% or 1 bpm, whichever is greater

• SpO2 accuracy* (within the range 70 – 100%),

• Wavelength range**: 500 – 1000 nm for all specified sensors

• Maximum optical output power: ≤ 15 mW for all specified sensors

 

Invasive blood pressure

• Measurement range: -40 to 360 mmHg

• Input sensitivity: 5 µV/V/mmHg

• Zero static offsets: up to ± 200 mmHg with ± 1 mmHg accuracy

• Gain accuracy

  - Accuracy: ± 1%

  - Drift: less than 0.05%/° C • Overall accuracy (including transducer): ± 4 mmHg or ± 4%, whichever is greater

• Volume displacement of CPJ840J6: 0.2 mm3/100 mmHg

• Warm up time of equipment and transducer: < 15 seconds

 

Noninvasive blood pressure (NBP)

• Technique: oscillometric, using stepwise deflation pressure

• Adult measurement range

  - Systolic: 30 – 270 mmHg (4.0 – 36.0 kPa)

  - Diastolic: 10 – 245 mmHg (1.3 – 32.7 kPa)

  - MAP: 20 – 255 mmHg (2.7 – 34.0 kPa)

• Pediatric measurement range

  - Systolic: 30 – 180 mmHg (4.0 – 24.0 kPa)

  - Diastolic: 10 – 150 mmHg (1.3 – 20.0 kPa)

  - MAP: 20 – 160 mmHg (2.7 – 21.3 kPa)

• Neonatal measurement range

  - Systolic: 30 – 130 mmHg (4.0 – 17.3 kPa)

  - Diastolic: 10 – 100 mmHg (1.3 – 13.3 kPa)

  - MAP: 20 – 120 mmHg (2.7 – 16.0 kPa

• Blood pressure accuracy

  - Maximum standard deviation: ≤ 8 mmHg

  - Maximum mean error: ± 5 mmHg

• Pulse rate range: 40 – 300 bpm

• Pulse rate accuracy (average over the NBP cycle)

  - 40 – 100 bpm: ± 5 bpm

  - 101 – 200 bpm: ± 5% of reading

  - 201 – 300 bpm: ± 10% of reading

• Initial cuff inflation

  - Adult: 160 mmHg (21.3 kPa)

  - Pediatric: 140 mmHg (18.7 kPa)

  - Neonatal: 100 mmHg (13.3 kPa)

• NBP intervals: automatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes and STAT

 

Temperature measurements

• Measurement range for all measurement sites: 0° to 50° C (32° to 122° F)

• Accuracy ± 0.1° C – without temperature probe

• Mode of operation: direct mode

• Heating and cooling transient response time: ≤ 150 s

 

Microstream CO2

• Measurement range: 0 – 150 mmHg

• Data sample rate: waveform sampling, 20 samples per second

• Flow rate: 50 ml/min, + 15 ml/min, –7.5 ml/min

• CO2 waveform resolution: 0.1 mmHg

• etCO2, imCO2 resolution: 1.0 mmHg

• Initialization and power-up time: 40 seconds (typical), 3 minutes maximum

• Total response time for adults/pediatrics is approximately 3.9 seconds, for 10% – 90% changes in CO2 concentration

• The maximum CO2 response time (with a standard-length FilterLine) is 5.3 seconds (typical).

• Calibration interval: initial calibration after one year or 1,200 hours, whichever comes first; then once per year, or every 4000 hours, whichever comes first

• Auto zero interval: once per hour (typical)

• Leak tightness: < 250 mBar/min when a 30% vacuum is invoked on the flow system

• Accuracy (for respiratory rates up to 80 rpm):

  - ± 2 mmHg in the range 0 mmHg – 38 mmHg

  - ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg in the range 39 mmHg – 150 mmHg

• Respiration rate range: 0 – 150 rpm

• Respiration accuracy

  - ± 1 rpm in the range 0 – 70 rpm

  - ± 2 rpm in the range 71 – 120 rpm

  - ± 3 rpm in the range 121 – 150 rpm

• Automatic barometric pressure: automatic pressure compensation

• Effects of cyclical pressure

  - Overpressure: + 100 cmH2O

  - Underpressure: –20 cmH2O

 

PHiliph Efficia CM10 CM12 CM15 Patient Monitor Parameter Board 0

  

Thank you for your time! If you want to explore more details about PHiliphhilip Efficia CM10 CM12 CM15 patient monitor parameter board, please let us know. Customer satisfaction. Our biggest pursuit!

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Anna

Tel: 86-15083619413

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.