logo
Tel:
Request A Quote
English
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000

TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000

  • TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000
  • TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000
  • TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000
  • TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000
TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000
Product Details:
Brand Name: Mindray
Model Number: TR6C-30-16650
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: TR6C-30-16650 Mindray PM7000 PM8000 PM9000 MEC1000 Patient Monitor Printer Brand: Mindray
Part No .: TR6C-30-16650 Type: Thermal Dot Array
Horizontal Resolution: 160 Dots/cm (at 25mm/s Recording Rate ) Vertical Resolution: 80 Dots /cm
Width Of The Recorder Paper: 50mm Length Of The Recorder Paper: 30M
Recording Rate: 25mm/s,50mm/s Recorded Waveforms: 2
Condition: Refurbished MOQ: One Piece
Highlight:

TR6C-30-16650 Patient Monitor Printer

,

Mindray PM7000 Patient Monitor Printer

,

MEC1000 Patient Monitor Printer

TR6C-30-16650 Mindray PM7000 PM8000 PM9000 MEC1000 Patient Monitor Printer

 

The monitor can be equipped with a thermal recorder. The performance of the recorder is the description as follows.

  • Record patient data and settings
  • Capture up to two waveforms.
  • Selectable recording speed: 25mm / s and 50mm / s.
  • The mounting grid is optional.
  • It supports multiple types of recording.

 

 

Recorder

 

Type Thermal dot array
Horizontal resolution 160 dots/cm (at 25mm/s recording rate )
Vertical resolution 80 dots /cm
Width of the recorder paper 50mm
Length of the recorder paper 30m
Recording rate 25mm/s,50mm/s
Recorded waveforms 2

 

Item name

Mindray PM7000 PM8000 PM9000 MEC1000 patient monitor printer TR6C-30-16650

 

Brand Mindray
Model TR6C-30-16650
Use place Hospital Devices; Medical Care; ICU; Medical Equipments and Accessories
Deliver time 3-5 days
Warranty 90 days

 

Recording type

  • The monitor supports the following types of recording:
  • Real-time recording: continuous real-time recording or 8-second real-time recording.
  • Automatic save
  • Alarm recording: Recording of measurement parameter alarm, ST segment or travel alarm.

Freeze the waveform lock.

  • GraPHiliphhilip log / trend table: trend graPHiliphhilip, trend table, NIBP measurements, alarm events. or record the rhythm
  • Recording of the CO measurement curve
  • Recording of blood circulation calculations.
  • Record the titration program.
  • OxyCRG Record
  • Checking the status record

 

real-time recording

Press the RECORD button on the panel to start realtime recording. Save current settings and waveform In the RECORD menu, you can set RT REC TIME to 8S or CONTINUUM.You can also select two waveforms for recording (REC WAVE 1 and REC WAVE 2). , the recorder prints only one waveform and all measurement parameters. If both are in the OFF position, the logger will print all measurement parameters only.

 

automatic recording

The monitor will start recording at the selected interval (TIMING REC TIME) and automatically record an 8 second waveform.

TR6C-30-16650 Patient Monitor Printer Mindray PM7000 PM8000 PM9000 MEC1000 0

Alarm recording

The alarm record contains a measurement parameter record. ST segment alarm recording and arrhythmia alarm recording

1. Parameter alarm recording

In case of parameter alarm The recorder will automatically record two waveforms for 8, 16 or 32 seconds (4, 8 or 16 seconds before the alarm).

2. ST segment alarm recording

In the event of an ST segment alarm, the recorder will automatically print 8, 16 or 32 seconds (4, 8 or 16 seconds before and after the alarm) and two ECG traces of all measured parameters.

3. Atrial fibrillation alarm recording

If an arrhythmia alarm occurs The recorder automatically prints 8 seconds (4 seconds before and after the alarm) and the ECG keeps track of all measured parameters.

 

If you have any interested in Mindray PM7000 PM8000 PM9000 MEC1000 patient monitor printer TR6C-30-16650,feel free to contact us .

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2025 patients-monitor.com. All Rights Reserved.