Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Module

GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX

GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX

  • GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX
  • GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX
  • GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX
  • GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX
GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX
Product Details:
Brand Name: GE
Model Number: D-fend Pro+
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Stock: In Stock Product Name: GE
Type: D-fend Pro+ Water Trap PN: D-fend Pro+
Warranty: 90days Color: Green Cup
Power Supply Source: Electric Feature: Professional,reliable,durable
Use With: E-sCO, E-sCOV And E-sCOVX Mode Of Transport: Expressage
Product State: In Good Shape Service: Online Technical Support Service
High Light:

D-fend Pro Water Trap

,

2087478-001 Water Trap

,

M1200227 Water Trap

GE CARESCAPE™ R860 D-fend Pro+ Water Trap single use green cup 2087478-001 M1200227 for E-sCO, E-sCOV and E-sCOVX

 

 


Brief Introduction

GE D-fend Pro+ Water Trap is use for airway module. The water trap has a hydroPhilipilipobic membrane that prevents condensed water and secretions from entering the airway module measuring chamber. The condensed water and secretions are collected in a washable container.

This water trap works with E-sCO, E-sCOV and E-sCOVX airway module with a gas exchange option that allows control of O2 consumption (VO2), carbon dioxide production (VCO2), energy expenditures (EE) and breathing apnea (RQ).

To provide accurate breathing to breathing measurement for respiratory gas exchange, the units algorithmally integrate side current gas concentrations (CO2 and O2) as well as flows and volumes resulting from each breath. This is done using the D-lite (+) /Pedi-lite (+) flow sensor along with a rapid paramagnetic oxygen sensor and an infrared gas table to measure CARBON DIOXIDE. Due to the principle of side current measurement, there is a delay of about 2.5 seconds in measurement, due to the time the sample moves across the sampling line to the module. The module syncs these concentrations and flows algorithmically.

To obtain the patient's oxygen consumption, the gas exchange unit measures the amount of oxygen inhaled and subtracts the amount of exhalation. CO2 production is measured by subtracting the amount of co2 inhaled from the amount of exhalation. These quantities can be obtained by multiplying each sample size measured by the corresponding gas concentration.

GE CARESCAPE™ R860 D-Fend Pro+ Water Trap Single Green Cup 2087478-001 M1200227 For E-SCO E-SCOV E-SCOVX 0

  1. Water trap latch
  2. Gas sampling line connector on the water trap
  3. D-fend Pro water trap

 

 

Features

  • Does not contain latex
  • Streamlined gas flow channels enable fast response of the gas measurement to provide reliable readings
  • Easy removal of water trap from the module
  • Provides firm locking of water trap to meet the need of various care areas
  • Does not contain lead (Pb), mercury (Hg), cadmium (Cd), hexavalent chromium (Cr (VI)), polybrominated biPhilipilipenyls (PBB) and polybrominated diPhilipilipenyl ethers (PBDE)
  • High filtration efficiency according to measurements by Nelson Laboratories Inc., USA
  • Withstands 6 cycles of disconnections and reconnections of the sampling line without breakages
  • RoHS compliant
  • Compatible with E-sCO, E-sCOV and E-sCOVX .

 

Alarm

 

Condition Cause Action
D-fend module is not detected by the installed airway module while the nebulizer is not in use. Occlusion detected in airway module gas sampling line or D-fend water trap. • Empty the D-fend water trap.
• Check for an occlusion in the airway module gas sampling line.
• Replace the airway module gas sampling line.
Sample tubing inside or outside the installed airway module is blocked or the water trap is occluded. The airway module gas sampling line or the Dfend water trap is not installed • Install the D-fend water trap.
• Check the airway module gas sampling line connection.
• Wait 30 seconds, and then press Home to resume gas sampling.
Residue buildup on the water trap membrane of the installed airway module. Buildup can decrease airflow. Occlusion detected in airway module D-fend filter. • Replace the D-fend water trap.

 

 

Thank you for your time! If you have other questions about our GE CARESCAPE™ R860 D-fend Pro+ Water Trap single use green cup 2087478-001 M1200227 for E-sCO, E-sCOV and E-sCOVX, please feel free to contact us. We are always ready to serve you.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.