Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Machine Parts

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital

  • GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital
  • GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital
  • GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital
  • GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital
GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital
Product Details:
Brand Name: GE
Certification: CE
Model Number: MAC2000
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: GE MAC 2000 ECG Analysis System For Repair Brand: GE
Item No.: Mac2000 Display Type: 7 In. Color TFT Display With Support Of Minimum 32K Colors
Display Resolution: WVGA Resolution – 800 X 480 Display Data: Heart Rate, Patient ID, Clock, Battery Power Indicator, Waveforms, Lead Lables, Speed, Gain And Filter Settings, Warning Messages, Prompts, Help Messages, And 12-lead Display
Height: 200 Mm Width: 390mm
Weight: Approx. 5 Kg Including Battery, Without Paper ECG Interpretation: Marquette* 12SL ECG Analysis Program For Adults And Pediatrics
Computerized Measurements: 12-lead Analysis ECG Analysis Frequency: 500 Or 1000 Samples/second/channel
Digital Sampling Rate: 16000 Samples/second/channel For Normal Data Acquisition Pace Sampling Rate: 75K Samples/second/channel
High Light:

ECG EKG Analysis System

,

GE MAC 2000 Analysis System

GE MAC 2000 ECG Analysis System For Repair

 

 

 

MAC 2000 ECG Analysis System

 

The MAC 2000 ECG Analysis System is a portable ECG acquisition, analysis and recording system designed for use by a trained operator in a hospital or medical professional's facility setting, as well as in a clinic, Philipilipysician's office, outreach center or any ECG for testing.

 

 

 

The MAC™ 2000 Electrocardiogram Analysis System is a portable device designed to acquire, analyze, display and record information on adult and pediatric populations in hospitals, medical Professional facilities, clinics, doctor's offices or outreach centers.

notes:

The pediatric population was defined as patients between the ages of 0 and 15 years.

The MAC™2000 ECG Analysis System offers the following modes of operation:

• Resting ECG mode

This mode is the default mode for your system.

 

• Arrhythmia patterns

This mode is intended to facilitate the automatic creation of documentation.

You can upgrade the basic system with two additional operating modes:

 

• Exercise mode for exercise stress test (optional)

This mode is used to test Philipilipysical exertion.

 

 

• RR analysis mode for RR interval analysis (optional)

 

This mode is used for RR interval analysis

 

The basic system prints 6 or 12 EKG derivatives and optionally offers the transmission and reception of EKG data to a central cardiovascular EKG information system. You can also upgrade with software options such as 12-lead ECG measurement and interpretation analysis.

GE MAC 2000 Resting ECG EKG Analysis System For Repair In Hospital 0

 

Contraindications

This system is not suitable for use in the following ways:

• During patient transport

• Equipped with high frequency surgical equipment

• As intracardiac application

• As a vital signs Philipilipysiological monitor

 

ECG Interpretation Marquette* 12SL ECG Analysis Program for Adults and Pediatrics
Computerized measurements 12-lead analysis
ECG analysis frequency 500 or 1000 samples/second/channel
Digital sampling rate 16000 samples/second/channel for normal data acquisition
Pace sampling rate 75K samples/second/channel
ECG on-screen preview On-screen preview of acquired 10 second ECG waveform
Acquisition mode Provides 10 seconds of instantaneous ECG acquisition
Dynamic range AC Differential ±5 mV, DC offset ±300 mV
Resolution 4.88 µV +/-1% per LSB @ 500 SPS
Frequency range 0.04 to 150 Hz
Low cut off frequency 0.04 Hz (ADS off), 0.56 Hz (ADS On)
High cut off frequency Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz
Common mode rejection >135 dB (with 50/60 Hz filter ON)
Input impedance >10MΩ @ 10 Hz
Lead detection All disconnected lead detection except RL & RA
Heart rate meter 30 to 300 BPM
Operating system Microsoft® Windows® CE 6.0
Start-up time Less than 30 seconds
Display type 7 in. color TFT display with support of minimum 32K colors
Display resolution WVGA resolution – 800 x 480
Display data Heart rate, patient ID, clock, battery power indicator, waveforms, lead lables, speed, gain and filter settings, warning messages, prompts, help messages, and 12-lead display
ECG Cables/Leadwires

• IEC/AHA Value 10LD Patient Cable/Leadwire

• 10-lead IEC/AHA Patient trunk cable

• 14-lead IEC/AHA Patient trunk cable

• IEC/AHA (Nst, Nax) Leadwire set (ECG 10-L w/resist, Banana)

• IEC/AHA Set of leadwires (4mm connector, 10 leads, defibrillator proof)

ECG Adapter

IEC/AHA Kit Adapter, 10 set Banana

Electrode Prep Pads, CLIP Universal GE 10/Pkg

Electrodes

• ECG Electrode Clamp (Large, 4/set)

• Baby MAC electrodes

• Silver Mactrode Plus 1000/CASE

• Electrode Application System KISS 10-lead without pump

• Electrode Application System KISS 12-lead without pump

Height 200 mm
Width 390mm
Depth 330mm
Weight Approx. 5 Kg including battery, without paper

 

 

 

 

 

 

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.