Product Name: | MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 City Technology Medical Oxygen O2 Gas Sensor Original New | Brand: | City Technology |
---|---|---|---|
Item No .: | MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 | Test Gas: | % O2 Error |
50% He / 50% O2: | < 1% | 60% N2 O / 40% O2: | < 1% |
2% Halothane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2: | < 1.5% | 2% Enflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2: | < 1.5% |
2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2: | < 1.5% | Condition: | New & Original |
Warranty: | 90 Days | Payment Method: | T/T ,Paypal ,Western Union |
Highlight: | Medical Oxygen O2 Gas Sensor,MOX-1 Oxygen O2 Gas Sensor |
MOX-1 MOX-2 MOX-3 MOX-4 Mox1 Mox2 Mox3 Mox4 City Technology Medical Oxygen O2 Gas Sensor Original New.
MOX-1 MOX-2 MOX-3 MOX-4 oxygen sensors are designed to monitor partial pressure of oxygen in anesthesia (excluding xenon), intensive care, neonatal incubators, and general oxygen monitors.
MOX2 sensors come with adapters that fit onto the sensor threads and are used to direct airflow to the sensor.
MOX2 Oxygen Sensor
Test Gas | % O2 Error |
50% He / 50% O2 | < 1% |
60% N2 O / 40% O2 | < 1% |
2% Halothane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% |
2% Enflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% |
2% Isoflurane / 40% O2 / 30% N2 0 / 5% CO2 / Bal N2 | < 1.5% |
MOX2 Pictures
OEM # | MOX-2 |
OEM | City Technology |
Condition | New and original |
Color | White, Clear |
Diameter | 1.16 in |
Humidity | 0 to 99% |
Measuring Range | 0 to 100% |
Power Requirements | 9 to 13 mV Signal Output |
Response Time | 13 sec |
Temperature Rating | 0 to 45 Deg C |
IMPORTANT: Connections can only be made with recommended mating parts.
Soldering to the sensor will damage it and void the warranty.
All performance data is based on cylinder gas measurements using a flow rate of 100 ml/min. Conditions were 20°C, 50% RH and 1013 mBar. For sensor performance data under other conditions, please contact City Tech.
Performance characteristics provide an overview of the performance of the sensors offered during the first 3 months. Over time, the output signal may drift below the lower limit.
Intended Use
These sensors are designed to monitor partial pressure of oxygen in anesthesia, intensive care, incubators, and general oxygen monitors.
Stabilisation time
Allow the instrument to stabilize for at least 15 minutes before calibration.
Cleaning and Disinfection
If the sensor is contaminated, it can be washed with distilled water and dried naturally. Sensors are not suitable for steam sterilization or exposure to chemicals such as ethylene oxide or hydrogen peroxide
Calibration interval
These sensors are designed to have minimal drift over their lifetime, but for maximum accuracy they should be calibrated in 100% oxygen prior to use.
FAQ :
1. Is the oxygen sensor expired?
We have expired and new date.
2.What’s your MOQ ?
Our MOQ is one piece .You can take one sample to check our quality .
3.Do you have price list or catalogue ?
As our stock is changing everyday ,it will be appreciated to check our website and send back pictures or part no to get price .
4.Can i have a discount ?
As our profit is very low ,if ordering more ,we can give you a discount .
If you have any interest in MOX-1 MOX-2 MOX-3 MOX-4 City Technology Medical Oxygen O2 gas sensor original new,feel free to contact us .Thank you .
Contact Person: Kiara
Tel: 8619854815217