Product Name: | M3016A PHiliph Mainstream CO2 MMS Module For PHiliph MP20 MP30 MP40 MP50 MP60 MP70 MP80 MP90 Patient Monitor | Brand: | PHiliph Healthcare |
---|---|---|---|
OEM #: | M3016A | Condition: | Refurbished |
Measuring Range: | -4 To 150 Mm Hg | Temperature Rating: | 0 To 45 Deg C |
Applicated Machine: | MP20 MP30 MP40 MP50 MP60 MP70 MP80 MP90 Patient Monitor | MOQ: | One Piece |
Warranty: | 90 Days | ||
Highlight: | PHiliph Mainstream CO2 MMS Module,M3016A CO2 MMS Module,MP40 MMS Module |
M3016A Measurement Server Expansion Working Principle
The specific application software for measuring the second pressure/temperature and CO2 runs on the main CPU of the measurement server. The pressure/temperature and CO2 front-end transmits the pre-processed PHiliphhilipysiological data to the application-specific software on the main CPU of the measurement server through the front-end link protocol. The temperature/pressure functions available on the extension are the same as those available on the server. The temperature/pressure options specific to the extension are T2 and P2. If you press the zero key on the server, all invasive pressure channels used will be zeroed. However, to set a separate zero-sum label for P2, use the soft keys on the monitor. If two temperatures are measured (one using the server and one using the extension), the server calculates the temperature difference (Delta Temp)
M3016A MeasurementServer extended hardware function description
The extension receives information signals (such as Temp/Press and mainstream CO2, and then the patient transmits the data to the monitor through the server-to-monitor link bar.
The mainstream CO2 extension is always used with the server. To function properly, both the server and the extension must have compatible software revisions.
Warning
Do not use measurement extensions with measurement servers that include version A software (A.XX.XX). Due to the lack of the software required to process the data from the extension, no additional measurements will be displayed. To check the software version, press the settings key and select the version.
Pairing servers with extensions can achieve the following goals:
• Measure the body temperature and invasive blood pressure of the same patient.
• Two temperature measurements of the same patient, including Delta Temp calculation function.
• Perform two invasive blood pressure measurements on the same patient.
Mainstream CO2 Measurement
The M3016A measurement server extension has mainstream carbon dioxide breathing gas measurement for Monitor monitoring equipment. It is intended to be used with the M3000A measurement server for adult, pediatric or neonatal patients, in the hospital environment, and during clinical users transporting patients inside and outside the hospital
CO2 breathing gas measurement indicates the efficiency of oxygen transfer from alveolar air to pulmonary capillary blood, and the efficiency of removing carbon dioxide from pulmonary capillary blood and transferring it to alveolar air.
CO2 breathing gas measurements are evaluated as the gas passes through the airway adapter on the patient’s intubation system
The CO2 breathing gas measurement value indicates the patient's overall breathing status.
The important concept of blood gas is
Airway Respiration Rate (AwRR)-the number of inhalations and exhalations per minute
End-tidal CO2 (ETCO2) The highest CO2 partial pressure measured during an exhalation
Minimum CO2 during inhalation Minimum CO2 partial pressure
Instantaneous CO2-the measured value of Co2 at any moment.
Ventilation-the movement of air in and out of the lungs through inhalation and exhalation.
Item | M3016A PHiliphhilip Mainstream CO2 MMS Module |
OEM | PHiliphhilip Healthcare |
OEM # | M3016A |
Condition | Refurbished |
Measuring Range | -4 to 150 mm Hg |
Temperature Rating | 0 to 45 Deg C |
Mainstream CO2 Features
This figure shows the user controls and mainstream connectors on the server
Mainstream CO2 Wave
The two calibration marks are located at 10% and 60% of the channel height. The lower calibration mark is marked with 0 mmHg (0.0 kPa) on all scales. The previous one can be adjusted from 20 mmHg (2kPa) to 100 mmHg (13 kPa) in steps of 10 mmHg (1kPa)
M3016A can be easily used with the following patient monitor series
M3016A #A02 (Press/Temp without Mainstream CO
Overview of the Measurement Server Extensions M3015A &
M3016A
Measurement Connectors for the M3016A Measurement Server
Extension