Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A

Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A

  • Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A
  • Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A
  • Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A
  • Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A
Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A
Product Details:
Brand Name: Philip Heartstart M4735A XL Battery
Model Number: M3516A 989803107041
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip Heartstart M4735A XL Battery Type: M3516A 989803107041
Application: Medical Equipment,ICU,hospital Device,defibrillator Warranty: 90days
Temperature Operating: 0º C To 55ºC Temperature Storage: -20º To 70ºC
Humidity: Up To 95% Relative Humidity Altitude Operating: Up To 15,000 Ft.
Altitude Storage: Up To 15,000 Ft. AC Line Powered:: 100-240 VAC, 50/60 Hz, 1.5A (Class 1)
Battery Powered: 12 V Rechargeable, SLA
High Light:

M4735A XL Defibrillator SLA Battery

,

M3516A Defibrillator SLA Battery

,

989803107041 Defibrillator SLA Battery

 

 Hospital Medical Equipment Parts Philipilip M4735A XL Defibrillator High Voltage Module Board

 

 

►Brief Introduction

The M4735A is powered by a rechargeable Sealed Lead Acid (SLA) battery (M3516A). Proper care of these batteries will ensure that they have the energy required to operate the M4735A and deliver the appropriate therapy. The M3516A battery differs from similar batteries in that it is capable of providing much higher current without causing an internal protection device to open and disconnect the battery.
The defibrillator will take longer to charge when powered by AC without a battery installed. To ensure optimal performance, always have a fully charged battery in the defibrillator, even when using AC power.
The repair PhilipilipilosoPhilipilipy for the SLA battery (M3516A) is unit replacement. If a battery fails, it is replaced, not repaired.

 

 

 

Power Indicator Matrix

 

INDICATORS SYSTEM STATE MEANING
AC POWER BATTERY CHARGING Connected to AC Mains? Battery in Place? Unit Power ON?
G = GREEN
OR = ORANGE/AMBER
Y = YES N = NO --- = don’t care  
OFF OFF N --- --- Normal
G OFF Y N --- Normal
G OR Y Y --- Battery is charging.
G G Y Y --- Battery at least 90% charged.

 

 

 

►Battery Capacity Test
The HeartStart XL uses the M3516A Battery Pack. It is rechargeable sealed lead acid battery. Battery maintenance begins when you receive a new battery and continues throughout the life of the battery.
As sealed lead acid batteries age due to usage and storage conditions, their capacity to store and deliver energy diminishes. The Battery Capacity Test provides a quantitative measure of battery capacity. Performing a Battery Capacity Test periodically over the life of the battery gives you an indication of how that battery is aging, and what level of performance it is capable of delivering.
A battery’s capacity is most affected by the duration of use and how deeply it is discharged before recharging, Therefore, some general guidelines for performing the Battery Capacity Test are as follow:

Hospital Medical Equipment Parts Philip M4735A XL Defibrillator High Voltage Module Board M3516A 0

 

To perform a Battery Capacity Test(CT).

  1. Turn the HeartStart XL off.
  2. Label the HeartStart XL to indicate to others that testing is in progress and the battery may not be used.
  3. Insert a charged battery.
  4. If an AC power cord is connected, unplug it. While pressing “Mark”, turn the Energy Select knob to AED on the start the test.
  5. Allow the test to proceed to completion. The test takes approximately three hours and is complete when test results print out and the device turns itself off.
  6. Review the test results and take the appropriate action, as follows:

Battery Capacity Test Results

If Then
Elapsed Time≥ 95 minutes
and
Low Battery time ≥ 10 minutes
1. The battery passed the test
2. Record "Pass CT" and the date on the bottom of the battery
3. Recharge the battery before use.
Elapsed Time< 95 minutes
or
Low Battery time < 10 minutes
1. The battery failed the test.
2. Record "Fail CT" and the date on the bottom of the battery.
3. Discard the battery appropriately.

 


 

Customer satisfaction. Our biggest pursuit! If you have any questions about Philipilip Heartstart M4735A XL defibrillator M3516A Sealed Lead Acid SLA Battery REF 989803107041, please feel free to contact us at any time, we are glad to answer them.

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.