Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001

Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001

  • Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001
  • Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001
  • Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001
  • Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001
Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001
Product Details:
Brand Name: Philip
Model Number: MP50
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip IntelliVue MP50 Patient Monitor Type: MP50
Application: Medical Equipment,ICU,hospital Warranty: 90days
Power Source: Electric Nominal Voltage: 110V—240v
State: Running Sweetly Supported Language: English/French/Italian/Spanish/Japanese/Hindi/Portuguese And All The Other Languages.
Sale Protection: If We Find Non-human Damage, We Will Be Free For You To Repair Or Returned Advantage: Specialized Engineers With 12 Years Of Experience
Function: Monitoring Patient's Health Condition Usage: Operating Room
Major Material: ABS+PC Fireproof Materials Key Words: Patient Monitor,medical Device
High Light:

Philip IntelliVue MP50 Patient Monitor Parts

,

M8085-61001 Patient Monitor Parts

,

M8085-66421 ECG LED Board

Hospital Medical Parts Philipilip IntelliVue MP50 Patient Monitor Connector ECG Out/Alarm LED Board M8085-66421 M8085-61001

 

 

► Brief Introduction

The alarm system can be configured to present either the traditional HP/Agilent/Philipilip alarm sounds or sounds compliant with the IEC 60601-1-8 Standard.

Alarm limits are permanently visible on the main screen. The Alarm Limits page provides a graPhilipilipic depiction of alarm limits in relation to the currently monitored measurement values and lets you adjust alarm limits. It also lets you preview wide and narrow automatic alarm limits before you apply them.

 

 

When an alarm limit is exceeded, it is signaled by the monitor in the following ways:
• an alarm tone sounds, graded according to severity
• an alarm message is shown on the screen, color-coded according to severity
• the numeric of the alarming measurement flashes on the screen
• alarm lamps flash for red and yellow alarms and are illuminated for technical INOPs
• the Remote Alarm Device signals the alarm visibly and audibly.

 


Alarms are graded and prioritized according to severity:
• Red Alarms*** identify a potentially life threatening situation for a patient.
• Yellow Alarms** indicate conditions violating preset vital signs limits.
• Technical Alarms (INOPS) are triggered by signal quality problems, equipment malfunction or equipment disconnect.
• The Silence function allows the user to switch off alarm tones with one touch or click while retaining visual alarm messages.
All alarms can be paused indefinitely or for a period of one, two, three, five, or 10 minutes.

 

 

► Removing the ECG Out/Alarm LED Board
1 Separate the back and front half of the monitor and lay the back half of the monitor on its back.
2 Remove the flat ribbon connector of the ECG Out/Alarm LED board from the main board and remove the 3 screws that hold the board and lightpipes.
NOTE To remove the flat ribbon cables with red connectors (e.g. Navigation Point cable) simply pull directly on the cable.

 

Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001 0

3 Lift the board out to the right so the ECG out connector is pulled out of the monitor housing.

Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001 1

4 Pull off the light pipe holder if necessary. It is snapped in on both sides of the board.

Philip IntelliVue MP50 Patient Monitor Parts Connector ECG Out Alarm LED Board M8085-66421 M8085-61001 2

Reassembly Note: Make sure the snaps and feet are properly hooked into the ECG Out board when reattaching the light pipe holder

 

 

 

► ECG Output/Marker Input (1/4” stereo Philipilipone jack with tip, ring, sleeve)

Connector 1/4” Philipilipone each with tip, ring, sleeve
Isolation 500 V
Signal Gain 320 to 3200
Full Scale on Display 3.2 V pp
Gain Error <20%
Baseline Offset <150 Mv
Bandwidth 1 to 80 Hz
Output ECG Output (ring):
Impedance ECG Output (ring): <2.2 KW ±20%
ECG Output/Marker Input (tip) <2.5 kW ±20%
Signal delay ≤30 ms


 

Thank you for your time and interest in Philipilip IntelliVue MP50 Patient Monitor Connector ECG Out/Alarm LED Board M8085-66421 M8085-61001.

"Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.