Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsECG Replacement Parts

PN 8000-0026 Zoll 3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019

PN 8000-0026 Zoll 3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019

  • PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019
  • PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019
  • PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019
  • PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019
PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019
Product Details:
Place of Origin: China
Brand Name: Zoll
Certification: CE
Model Number: 8000-0026
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: Zoll 3lead ECG Patient Cable (12Ft)PN 8000-0026 New Original Brand: Zoll
REF: 8000-0026 Condition: New & Original
Number Of Channels: 3 Country/Region Of Manufacture: China
MOQ: One Piece Warranty: 90 Days
Color: Gray Lot: 20517621019
High Light:

PN 8000-0026 ECG Patient Cable

,

12Ft ECG Patient Cable

,

20517621019 ECG Patient Cable

Zoll 3lead ECG patient cable (12Ft)PN 8000-0026 new original

 

 

Quick Judgement and Maintenance of Lead Wire Failure of ECG

During the use of the electrocardiograPhilipilip, poor contact or disconnection of a certain lead may affect the normal tracing of the electrocardiogram due to factors such as the lead wire is often pulled and twisted. It is a common type of electrocardiograPhilipilip failure. Now summarizes the method of using the electrocardiograPhilipilip itself to judge the fault.

 

Trouble Philipilipenomenon: abnormal or serious interference of the electrocardiogram waveform of a certain lead or all leads occurs when doing an electrocardiogram for a normal person.

 

Failure analysis: The lead wires of the electrocardiograPhilipilip are composed of four red, yellow, blue, and black limbs and five chest leads. When it works, it sends the electrocardiograPhilipilip signal obtained on the electrode to the input end of the electrocardiograPhilipilip. For tracing after magnification. According to the principle of ECG generation and the connection method of the electrodes, use Table 1 to find out a certain faulty lead wire.

 

 

PN 8000-0026 Zoll  3 Lead ECG Patient Cable 12Ft Medical Device Spare Parts Lot 20517621019

Troubleshooting: After finding the faulty lead wire, first determine its fault location. Most of the faults are near the lead wire electrode, and the Philipilipenomenon is that when the hand is pulled there, there is a sense of extension. When touched by the hand, it is softer and thinner than other places. For this reason, it can be above the fault point. After disconnecting at ~5cm, unplug the core wire and electrode welding or core wire and core wire, shield and shield welding, pay attention to the shield not to connect with the core wire. Then use insulating tape or put on the heat-shrinkable heat-shrinkable insulation welding joint before welding. Turn it on again, and all the leads of the ECG are normal.

 

Item name Zoll 3lead ECG patient cable (12Ft)PN 8000-0026 new original-
Brand Zoll
Model 8000-0026
Use place Hospital Devices; Medical Care; ICU; Medical Equipments and Accessories
Deliver time 3-5 days
Warranty 90 days

 

 

Model number for each brands are as follows :

 

GE

Patient monitor :B105 ,B125,B450,B650 ,B20i ,B30 ,DASH3000,DASH4000,DASH5000,DASH2500

ECG/EKG :MAC800 ,MAC1200,MAC400 ,MAC5000 ,MAC5500

 

 

Philipilip

Patient monitor :MP20,MP30,MP40,MP50,MP60,MP70,MP80,MP90,VM4,VM6,VM8, MX600, MX700, MX800 ,MX400,MX450

Fetal monitor :FM20,FM30

ECG :TC10,TC20,TC30

Defibrillator :M3543A,M3535A,M3536A.Heartstart XL+

 

Mindray

Defibrillator :D1,D2,D3,D5,D6,

Patient monitor :MEC-1000,MEC-2000,IMEC10,IMEC12,BeneVision N1

MP6000,MP7000,MP8000,MP9000

BeneView T5 ,BeneView T6,BeneView T8

 

Nihon Kohden

Defibrillator :TEC-5521C,TEC-5531C,TEC-5631C,TEC-7621C,TEC-7631C

ECG/EKG:ECG 1250P,ECG-1250A,ECG-1350,cardiofax S,cardiofax Q

 

Zoll

Defibrillator:M series ,E series

 

Med-tronic

Defibrillator :Lifepack 12 ,lifepack 20 ,lifepack 1000

 

Masima

Masima SET Radical-7 pulse oximeter,Masima 9 pin Adult Finger clip Sensor Model LNCS DCO PN 1863,Masima rainbow Rc-12 patient cable

 

Notes:

For models ,spare parts and accessories without listing above ,feel free to contact us .We have sufficient stock for used medical device.

 

 

 

 

 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.