China World Technology Medical Equipment Service Group
Win-win together!
Brand Name: | Philip |
Model Number: | MP2 |
Minimum Order Quantity: | 1 |
---|---|
Delivery Time: | 3-5 working days |
Payment Terms: | T/T, Western Union,PayPal |
Product Name: | Philip MP2 Patient Monitor Battery Board | Type: | MP2 |
---|---|---|---|
Application: | Medical Equipment,ICU,hospital Device | Warranty: | 90days |
Color: | White | Index Terms: | Battery Board |
Apply For: | Patient Monitor | Product Conditions: | Run Well |
Rated Voltage: | 110V—240v | Major Materials: | Plastic, PCB |
Product Peculiarity: | Durable In Use,Professional, Reliable | Minimum Order Quantity: | 1unit |
Stock Status: | On Sale | Mode Of Transport: | Express Delivery |
Manage Spirit: | Sincere And Trustworthy | ||
High Light: | MP2 Patient Monitor Battery Power Board,ICU Patient Monitor Battery Power Board |
Philipilip MP2 Patient Monitor Battery Board Power Board Medical Equipment Hospital Device
►Quick Details
Brand |
Philipilip |
Type | MP2 |
Warranty | 90 Days |
Shipping Date | 3-5 Working Days |
Application | Hospital Devices; Medical Care; ICU; Medical Equipments and Accessories |
► Removing the Power Board
1. Remove the battery, handle, display, NBP pump first.
2. Remove the nameplate by moving it to the side. There will be a slight resistance when removing the nameplate. You may need to loosen the locking mechanism with a screwdriver before pulling off the nameplate..
3.Carefully lift up the power board only a few millimeters in order to loosen the connection to the main board, then completely disconnect the power board from the main board by pressing gently on the black transformer. Make sure the ECG Sync Pulse Out connector and cable is not damaged.
4. Remove the power board by pushing up the MSL connector. Due to the sealing there will be a strong resistance when removing the board.
► Reassembly Procedure
1. Insert the SRL cover into the prepared slots on the power board. The two grey dots on the plastic part must be next to the MSL connector.
2. Make sure that after it is plugged into the power board, the cover is parallel to the power board and that the MSL connector and the cover form a line.
3. Insert the power board into the guiding rail on the housing and make sure the connection to the main board is established correctly
4. When the power board is connected to the main board, insert the name plate into the guiding of the power board.
NOTE: Sometimes the name plate does not slide correctly into the dovetail locking mechanism. Make sure that the MSL power board is pressed down completely.
► Packing and Shipping Terms
All machines and components are transported by pallets or cartons to ensure the safety in the transmission process. As an international manufacturer, we provide medical devices, insurance and tracking standards around the world using trusted messengers. It is very important for us to deliver your goods to you accurately, quickly and safely. We have been trying to provide the best freight service. Shipping depends on where you are, what you order and how quickly you want your package to be delivered. If you have any questions, please feel free to contact us.
As for the delivery time, we will try our best to process the order and ship it as soon as possible. Please be patient and keep in touch with us. Generally speaking, most orders will be shipped within 3 to 5 working days and arrive on time. However, on busy days, shipment may be delayed by more than 5 working days. If you need your goods urgently, please be sure to confirm with us before placing an order.
► Purchase Notes
Before buying, carefully consider what kind of product you want, new or old. Please rest assured that both new and used medical equipment will be thoroughly inspected by our certified engineers to ensure complete functionality, so please rest assured to purchase. All the products we sell are running well. Finally, customers will receive high-quality refurbished or brand-new medical equipment, ready to use, which is a great convenience and improves your work efficiency. If you have any questions about product quality, please don't hesitate to contact us.
► Quality Guarantee
Our company have one division of labour on the basis of specialization, highly cooperative group, rich technical force of medical machines development. Our expert team provides prompt, dependable solutions for sales and repairs on patient monitor, defibrillator machine, ECG/EKG machine and other accessories or repair parts. We have been always focusing on producing superior products and providing first-class customer service. What calls for special attention is that there are both brand new and second-hand products for sell. Please remember to carefully distinguish them when placing your orders. Otherwise, it will cause unnecessary troubles. If you have any doubts about the product quality, please don’t hesitate to contact us. We will reply to you as quickly as possible.
► Returns Policy
Dear Sir or lady, please note that new and used medical machines are sent out for at least 90 days warranty period. They are not allowed to leave the workshop completely by our engineers to test each machine with the most concerned and unit, and ensure that they are 100% effective equipment. Of course, we are confident that you will be satisfied with our products and services. But if you are not, please contact us as soon as possible, if you find any problems. Our ultimate goal is to develop and sell the best products to customers around the world. Customer satisfaction is our biggest pursuit.
► Notices
Before placing orders, there are some important issues that need to be paid attention to. For the purpose of promoting the business, please read the following items with patience and carefully. Firstly, please be sure to keep in mind to look over all the pictures patiently before purchasing to ensure the product you’re browsing is exactly what you want to buy. It is of vital importance to do so because pictures are also significant references of the product description. Secondly, the buyer is responsible for all the customs fees including all taxes and duties. Therefore, you have to make sure the machine you are ordering can be imported into your country. In a word, don’t forget to check out all related information when placing your orders.
If you are interested in Philipilip MP2 Patient Monitor Battery Power Board, welcome to place your orders. Early order early shipment!
Customer satisfaction. Our biggest pursuit! Thank you for your time!
►
Contact Person: Anna Hu
Tel: +8615083619413