Send Message
Tel:
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group

China World Technology Medical Equipment Service Group

Win-win together!

Home ProductsPatient Monitor Parts

Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911

Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911

  • Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911
  • Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911
  • Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911
  • Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911
Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911
Product Details:
Brand Name: Philip
Model Number: VS2+
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Philip VS2+ Monitor Pump NBP Module Type: 453564196911
Application: Philip VS2+ Monitor Warranty: 90days
Color: White Product Condition: In Good Working Order
KeyWords: Patient Monitor Pump Minimum Purchase Contract: 1pcs
Applications Scenes: Hospital, Clinic, Hospital Room, ICU,etc Goodness: Original,Professional Technical Team
Sale Protection: If There Are Any Problems Caused By Us, We Will Be Free For You To Repair Or Returned Management Aims: Advanced Technology, High-quality Products, Attentive Service
Language Support Library: English,French,Italian,Spanish,Russian,Arabic, German,etc Inventory: Sufficient Inventory
Method Of Transport: Express Delivery

 

Hospital Medical Equipment Philipilip VS2+ monitor pump NBP Module 453564196911

 

 

Brief Introduction

Philipilip VS2+ monitor pump NBP Module 453564196911 processing uses oscillograPhilipilipy to provide the required measurements at selected time intervals. The technology uses inflatable sPhilipilipygmomanometer cuff, similar to the cuff that clinicians routinely use
The measured values. The electric pump initially inflates the cuff to about 160 mmHg (adult mode) at the default initial inflating pressure, at which point the pressure effectively blocks blood flow. Then, under the control of the monitor, the pressure in the cuff is gradually reduced while the pressure sensor detects the pressure and transmits the parameter signal to the NBP input circuit. As the pressure decreases, blood flows through the previously blocked artery and changes the transducer measurements. The point at which the oscillation increases sharply is defined as the systolic pressure. As the cuff continues to deflate, the oscillation amplitude increases to a maximum and then decreases. The peak oscillation amplitude is defined as the mean arterial pressure. The point at which the system detects a rapid drop in oscillation is defined as diastolic blood pressure.

After replacing the NBP module, you have to reset the NBP cycle count and run the NBP test.

 

 

NBP assembly and circuits

NBP components and circuits contain the following elements:
1. pump
2. Valves (2 valve system for relief and relief)

3. Manifold
4. Filter
5. Pressure measurement and control circuit
The pressure data is converted to a digital format and sent to the processor. The NBP pump uses the oscillograPhilipilipic method of stepwise pressure discharge. Pump software eliminates most ambient noise and motion interference. Suitable for neonates, children and adult patients. Blood pressure ranges are: systolic, 30-255 mmHg and diastolic, 15-220 mmHg. Accuracy is ±5 mmHg, standard deviation is not greater than 8 mmHg.

Hospital Medical Equipment Philip VS2+ monitor pump NBP Module 453564196911 0

 

 NBP Specifications

  – Oscillometric using stepwise deflation pressure
Adult Measurement Range: – Systolic: 30–270 mmHg (4.0–36.0 kPa)
– Diastolic: 10–245 mmHg (1.3–32.7 kPa)
– MAP: 20 – 255 mmHg (2.7–34.0 kPa)
Pediatric Measurement Range: – Systolic: 30–180 mmHg (4.0–24.0 kPa)
– Diastolic: 10–150 mmHg (1.3–20.0 kPa)
– MAP: 20–160 mmHg (2.7–21.3 kPa)
Neonatal Measurement Range: – Systolic: 30–130 mmHg (4.0–17.0 kPa)
– Diastolic: 10–100 mmHg (1.3–13.3 kPa)
– MAP: 20–120 mmHg (2.7–16.0 kPa)
NBP Intervals: – Automatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90 or 120 minutes
– Up to 1 interval can be defined

 

 

 Packing and Delivery Arrangements

All machines and units are delivered on pallets or carton so as to make sure the safety to the full extent during the transmission. As a international manufacturer, we deliver medical equipment all over the world, insured and tracked as standard using trusted couriers. It is vitally important for us to delivery your items to you accurately, quickly and safely. We have always been making great efforts to provide the best shipment service. The freight cost largely on your location, what you have ordered and how quickly you’d like your package to be delivered. If you have any problem, please contact us at any time. We will respond you as soon as possible.

 

 

 Disclaimer

To make sure the deal runs successfully and efficiently, please learn about and agree to the following clauses and terms. There are two things that you need to know well. The first thing is that you’d better bear in mind to look through all the product pictures with patience when purchasing so that you can confirm the item you are viewing is just what you are looking for and need to buy. It is absolutely necessary to do so as product pictures also play essential roles in product description, which helps you understand the product more intuitively and detailedly. The second thing comes to the customs fees. Please kindly know that the buyer is responsible for the customs fees such as all taxes and duties. Consequently, before paying for orders you must check out that the equipment your are ordering is allowed to imported into your country. That is to say, remember to read all the relevant information before ordering.

 

 

 

 Warranty Policy

Please kindly note that both new and second-hand medical machine are dispatched with at least 90 days warranty period and they are not allowed to leave our workshops before being completely tested by our engineers who will treat each machine and unit with the most care to ensure they are all 100% efficient equipment. Of course, we are confident to let you satisfy with our products and service. But if you are not, please contact us as soon as you find any problem. Our ultimate goal is to strive to develop and sell the best products to the customers all over the world. Customer's satisfaction is our greatest pursuit.

 

 

 Repair Policy

Apart from specializing in selling medical devices, accessories and repair parts such as patient monitor, defibrillator machine, patient monitor printer, ECG machine, EKG machine, main board, batteries and so on, we also engage in providing medical equipments or modules repair service. So if you have any that sort of machine or modules which in need of repair, please feel free to contact us at any time. Moreover, what need to pay attention to is that you have to make sure the repair item is unopened and has never been repaired before. And items lack of component is unacceptable. Accordingly, check out your item before shipping.

 

 

 More For You

Under normal conditions, whether our new or used items usually comes with a three-month warranty period. That is to say you are allowed to change or get the machines repaired under guarantee if you find there is any problem about the product you purchased. However, take it easy please. We hope you will be pleased with our products and service down to the ground. Moreover, we have a lot of confidence to satisfy you as our goods are all in perfectly high quality. Years of sales experience makes us handle this sort of issues skillfully. Customers’ satisfaction is the goal that we are always pursuing.

 

If you have any questions about  Philipilip VS2+ monitor pump NBP Module 453564196911, please feel free to contact us at any time, we are glad to answer them. Thank you for your time! 

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.