Product Details:
Brand Name: Valleylab
Model Number: FORCE EZ
Payment & Shipping Terms:
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T, Western Union,PayPal
Contact Now
Detailed Product Description
Product Name: Valleylab SN: FORCE EZ E
Product Superiority: DefibrillatorElectrosurgical Generator Applications Scenes: ICU, Emergency, ICU Room And Operating Room
Key Word: Electrosurgical Generator Machine After-sale Service: In The Warranty Period And Non-human Damage Can Go To The Sale Free Of Charge For New
Product Status: In Good Form Company Tenet: Original Assembled Real Product, Quality Guarantee, Deliver On Time, Preference Price
Stock Status: Stock Available Width: 40.6cm (16 In.)
Depth: 39.5cm (15.6 In.) Height: 12.7cm (5 In.)
Weight: < 6.8 Kg (<15 Lbs) Ambient Temperature Range: 10℃ To 40℃ (50℉ To 104℉ )
Relative Humidity: 30% To 75%, Noncondensing
High Light:

12.7cm Height Electrosurgical Generator Machine

,

ICU Room Electrosurgical Generator Machine

Valleylab FORCE EZ Electrosurgical Generator Machine

 

 

 

► Brief Introduction

The Valleylab Force EX Electrosurgical Generator is an isolated output electrosurigical generator that provides the power for cutting, desiccating, and fulgurating tissue during electrosurgery. The generator is specifically designed for use in bipolar or monopolar electrosurgery,

It includes the following features:

  • Instant Response Technology
  • Standard bipolar mode
  • Two monopolar cut modes: pure and blend
  • Two monopolar coag modes: low (desiccate) and high (fulgurate)
  • The Valleybal REM Contact Quality Monitoring System, which protects patients against burns at the patient return electrode site
  • User selectable coag settings
  • User selectable default settings
  • Adjustable activation tone volume
  • Force GSU and Force Argon system compatibility

 

Front Panel

Valleylab FORCE EZ Electrosurgical Generator Machine 12.7cm Height For ICU Room 0

  1. Bipolar Indicator
  2. Bipolar Display
  3. Bipolar Power
  4. Cut Indicator
  5. Cut Display
  6. Cut Power Control Knob
  7. Pure Button
  8. Blend Button
  9. Coag Indicator
  10. Coag Display
  11. Coag Power Control Knob
  12. Low(Desiccate) Button
  13. High(Fulgurate) Button
  14. REM Alarm Indicator
  15. Patiient Return Electrode Receptacle
  16. Monopolar Instrument Receptacle
  17. Accessory Instrument Receptacle
  18. Footswitch Receptacle, Button, and Indicators
  19. Bipolar Instrument Receptacle
  20. Power Switch

 

Performance Characteristics

 

Width 40.6cm (16 in.)
Depth 39.5cm (15.6 in.)
Height 12.7cm (5 in.)
Weight < 6.8 kg (<15 lbs)
Ambient Temperature Range 10℃ to 40℃ (50℉ to 104℉ )
Relative Humidity 30% to 75%, noncondensing
AtmosPhilipiliperic Pressure 700 to 1060 millibars

 

 

 

List of Components
The Valleylab Force EZ Electrosurgical Generator is a self-contained unit. It consists of a main enclosure (cover and base) and power cord. It includes the following components:
Front panel – the power switch; controls for setting the modes and output power;a footswitch receptacle and button for selecting bipolar or accessory output; receptacles for connecting electrosurgical accessories, and indicators that alert you to the selected modes and the patient returen electrode status.
Rear panl – the power entry module, volume control, two footswitch receptacles, equipotential grounding lug, and option panel.
Internal Components – include the Conttol (microcontroller) board, Display board, Footswitch board, Power Supply/ Radio Frequency (RF) board, low voltage power supply, and heat sinks.
A handle is located on the underside of the classis.

 

 

About company

We have supply the Parts, Accessories and medical equipment of Patient Monitor, Defibrillator Machine, ECG Machine, Ventilator, Anesthesia Machine, Ultrasound such as
GE,
Philipilip,
Mindray,
Goldway,
Nihon Kohden,
Med-tronic,
Masima,
Drager,
Edan,
Zoll,
etc.

 

Please kindly contact us, if you are interested in Med-tronic Valleylab FORCE EZ Electrosurgical Generator Machine, Thank you!

 

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Rita

Tel: 8618279091952

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.