Product Details:
Place of Origin: Japan
Brand Name: Nihon Kohden
Certification: CE
Model Number: TEC-7621K TEC-7621C
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Packaging Details: Carton
Delivery Time: 3-5 working days
Payment Terms: T/T(wire transfer), Western Union, Paypal
Contact Now
Detailed Product Description
Product Name: TEC-7621K TEC-7621C NIHON KOHDEN Cardiolife Defibrillator New Condition Brand: Nihon Kohden
Model Number: TEC-7621K TEC-7621C Display Size: 5.7inch
Segment Analyzed, Sec (ANALYSIS): 4 Analysis Time, Sec (ANALYSIS): 6-12
Threshold, Bpm (V Tach Rate): >180 Threshold, MV (VF Amplitude): >0.1
AC POWER: Yes Condition: New & Original
Warranty: 90 Days MOQ: One Piece
Highlight:

TEC-7621K Cardiolife Defibrillator

,

TEC-7621C Cardiolife Defibrillator

,

Nihon Kohden Cardiolife Defibrillator

TEC-7621K TEC-7621C NIHON KOHDEN Cardiolife Defibrillator New Condition

 

Nihon Kohden TEC-7621K has a 5.7-inch large screen, color TFT LCD display, integrates defibrillation and monitoring.

 

Optional "AED" automatic external defibrillation function, and optional AED voice prompts.

 

Multi-parameter monitoring function, in addition to ECG and heart rate monitoring, SPO2, CO2 plug-in and NIBP plug-in can be purchased to realize multi-parameter monitoring and increase the usable range of the machine.

 

Defibrillation type: manual, synchronous, AED

 

MODEL TEC-7621K
Segment analyzed, sec (ANALYSIS) 4
Analysis time, sec (ANALYSIS) 6-12
threshold, bpm (V tach rate) >180
threshold, mV (VF amplitude) >0.1
AC POWER Yes

 

Output energy (50Ω in parallel):

 

TEC-7621C: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300 and 360 Joules

 

Energy accuracy:

 

2 joules: ±0.5 joules

 

3 joules: ±1 joule

 

5 to 15 joules: ±2 joules

 

20 to 360 joules (TEC-7621C): ±10%

 

Energy limitation: 50 joules of internal defibrillation

 

Output waveform:

 

TEC-7621C: Edmark, single pulse wave (parallel 50Ω)

 

Charging time:

 

TEC-7621C:

 

AC work: 0 to 360 joules, 5 seconds longer

 

AC work: 0 to 200 joules, 3 seconds

 

After the new battery is fully charged, when the outside temperature is 20 degrees Celsius: 0 to 270/360 Joules, 10 seconds longer

 

Charging display: display the charged energy value

 

Charging status indicator: sound after fully charged

 

Synchronous discharge: provided

 

Discharge time:

 

From the top of the R wave to the top of the discharge wave:

 

Use the ECG lead wire to detect the ECG or the electrode plate to detect the ECG: within 60ms

 

Use external input ECG signal: within 25ms

 

Large continuous cycle of charging and discharging at 270/360 Joules:

 

60 times: 3 times per minute, need to stop and rest for 1 minute every 1 minute of work

 

15 times: 3 times per minute, no rest period required

 

Discharge test: When 2 to 270/360 joules pass the test load, the "test normal" message will be displayed. When the selected energy fails to pass the test load, "Test Failed" is displayed.

 

Automatic internal discharge: The energy stored in the machine can realize automatic internal discharge under the following conditions:

 

1) The energy knob is turned to the discharge position

 

2) The power is turned off

 

3) The electrode plate is pulled out

 

4) Exceed the preset time after charging

 

5) The disposable electrode placed on the patient is removed

 

Nihon Kohden Cardiolife Defibrillator TEC-7621K TEC-7621C New Condition 0

 

Electrode plate size:

 

Adult: 76X106mm

 

Children: 46X54mm

 

Length of electrode plate connection: 2.0m or longer

 

Electrode connection impedance:

 

Indicated by 3 indicator lights of different colors on the electrode plate handle

 

Green light: 0 to 100Ω

 

Yellow light: 100 to 200Ω

 

Orange light: greater than 100Ω

 

u Guardianship

 

Display: 5.7 inches, color LCD

 

Effective display range: 115X86mm

 

Number of stitches: 1 (ECG), or 3 (ECG, pulse*, end-tidal carbon dioxide*)

 

Use optional DSI access unit

 

Scan length: 97mm

 

Scanning speed: 25 or 50 mm/s (cardiograPhilipilip, pulse wave), 6.25 or 1.2550 mm/s (end tidal carbon dioxide)

 

Amplitude limit: 40 mm

 

Baseline position: fixed

 

Letter and number display: heart rate, blood oxygen saturation value*, pulse rate*, end-tidal carbon dioxide value*, number of breaths*, non-invasive blood pressure value** (systolic blood pressure, diastolic blood pressure, mean blood pressure)

 

Use optional DSI access unit

 

Use the optional non-invasive blood pressure unit

 

Other indications: synchronization, charging, discharging, fixed mode, demand mode, ~ (AC working), battery mark (indicating remaining working time), information

 

Alarm system:

 

Heart rate/pulse rate upper/lower limit (in steps of 5 beats per second)

 

Upper limit: 20 to 300 times per second, closed

 

Lower limit: 15 to 295 times per second, off

 

Upper/lower limit of blood oxygen saturation (in 1% steps)

 

Upper limit: 51 to, closed

 

Lower limit: 50 to 99%, closed

 

Pulse rate upper/lower limit (in steps of 5 beats per second)

Contact Details
China World Technology Medical Equipment Service Group

Contact Person: Kiara

Tel: 8619854815217

Send your inquiry directly to us
China World Technology Medical Equipment Service Group
TianHe District,GuangZhou,GuangDong
Tel:86-198-5481-5217
Mobile Site Privacy Policy | China Good Quality Used Patient Monitor Supplier. © 2021 - 2024 patients-monitor.com. All Rights Reserved.